Dissolution testing of a poorly soluble compound using the flow-through cell dissolution apparatus

被引:45
作者
Bhattachar, SN [1 ]
Wesley, JA [1 ]
Fioritto, A [1 ]
Martin, PJ [1 ]
Babu, SR [1 ]
机构
[1] Pfizer Global R&D, Ann Arbor, MI 48105 USA
关键词
dissolution testing; flow-through dissolution method; high throughput screening;
D O I
10.1016/S0378-5173(02)00027-3
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Dissolution of Pfizer Compound PD198306, a poorly soluble compound, was studied in 25 mM pH 9 sodium phosphate solution with 0.5% SLS using the flow-through cell dissolution apparatus. Unmicronized and micronized drug powders were tested. Several methods of loading the drug powder into the flow-through dissolution cells and their impact on dissolution were investigated. The influence of flow rate of the dissolution medium on the rate and extent of dissolution were studied. PD198306 has poor wettability even in the presence of 0.5% SLS. It was found that loading the drug powder into the dissolution cell in the form of a suspension provided the best dissolution profile in terms of the rate and extent of dissolution. The now rate of 4 ml/min resulted in good particle size discrimination. (C) 2002 Elsevier Science B.V. All rights reserved.