Anodic stripping voltammetry of copper at insonated glassy carbon-based electrodes:: application to the determination of copper in beer

被引:95
作者
Agra-Gutiérrez, C [1 ]
Hardcastle, JL [1 ]
Ball, JC [1 ]
Compton, RG [1 ]
机构
[1] Univ Oxford, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
D O I
10.1039/a902974e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The suitability of ultrasound-assisted anodic stripping voltammetry (sono-ASV) for the detection of total copper content in beer using both mercury thin film and glassy carbon electrodes has been investigated. An immersion horn probe is introduced into a small thermostatted conventional three electrode cell (20 cm(3)) opposite the working electrode: an ex situ mercury plated Nafion(R)-coated mercury film electrode or a bare glassy carbon electrode. Minimal sample pre-treatment is required which consists of acidification of the beer with dilute nitric acid and out-gassing with argon. After the deposition of copper (as the metal or its amalgam) on the electrode in the presence of ultrasound, a square wave scan is employed to get the analytical signal. In the absence of ultrasound, electrode passivation by organic species and lower rates of mass transport prevent the observation of any measurable signals. In situ cavitational cleaning of the electrode by insonation maintains the electrode activity. Total copper content levels in the range of 100 to 300 mu g Cu L-1 were determined by sono-ASV using both electrode substrates and showed excellent agreement with values provided by an independent method. This highlights the validity of the sono-ASV method as a useful electroanalytical technique in hostile media.
引用
收藏
页码:1053 / 1057
页数:5
相关论文
共 58 条
[1]  
Agra-Gutiérrez C, 1999, ELECTROANAL, V11, P16, DOI 10.1002/(SICI)1521-4109(199901)11:1<16::AID-ELAN16>3.0.CO
[2]  
2-E
[3]  
Agra-Gutierrez C, 1998, ELECTROANAL, V10, P603, DOI 10.1002/(SICI)1521-4109(199807)10:9<603::AID-ELAN603>3.3.CO
[4]  
2-D
[5]  
Agra-Gutierroz C, 1998, ELECTROANAL, V10, P204, DOI 10.1002/(SICI)1521-4109(199803)10:3<204::AID-ELAN204>3.0.CO
[6]  
2-F
[7]   Sono-electroanalysis: Application to the detection of lead in wine [J].
Akkermans, RP ;
Ball, JC ;
Rebbitt, TO ;
Marken, F ;
Compton, RG .
ELECTROCHIMICA ACTA, 1998, 43 (23) :3443-3449
[8]   DETERMINATION OF TRACE QUANTITIES OF HEAVY-METALS IN FOOD BY ANODIC VOLTAMMETRY - DETERMINATION OF CADMIUM, LEAD AND COPPER IN BEER [J].
ALIAKBAR, A ;
POPL, M .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1985, 50 (05) :1141-1146
[9]  
Baldo MA, 1998, ELECTROANAL, V10, P410, DOI 10.1002/(SICI)1521-4109(199805)10:6<410::AID-ELAN410>3.0.CO
[10]  
2-A