Comparison of the Frequency Doubling Technology screening algorithm and the Humphrey 24-2 SITA-FAST in a large eye screening

被引:18
作者
Allen, CS
Sponsel, WE
Trigo, Y
Dirks, MS
Flynn, WJ
机构
[1] Univ Texas, Hlth Sci Ctr, Dept Ophthalmol, San Antonio, TX 78229 USA
[2] San Antonio Uniformed Serv Hlth Educ Consortium O, San Antonio, TX USA
[3] Brooke Army Med Ctr, Ft Sam Houston, San Antonio, TX USA
[4] Wilford Hall USAF Med Ctr, San Antonio, TX 78236 USA
关键词
frequency doubling perimetry; glaucoma; Humphrey Field Analyser; screening;
D O I
10.1046/j.1442-9071.2002.00478.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the Frequency Doubling Technology (FDT) C20-1 screening algorithm and the Humphrey Field Analyser II (HFA) 24-2 SITA-FAST in a large eye screening. Methods: In a non-randomized, prospective, free eye screening, the FDT Screening Protocol (C20-1 Screening Algorithm) was administered to 574 attendees (422 men and 152. women, average age 64, range 17-89 years) of the 1998 Veterans of Foreign Wars (VFW) Convention in San Antonio, Texas. Individuals who failed the FDT (two or more misses out of [7 locations) immediately underwent white-on-white threshold visual field perimetry (HFA 24-2, SITA-FAST). Humphrey visual field analysis included STATPAC and masked evaluations by three glaucoma specialists. Results: Approximately one-tenth of the VFW conference attendees voluntarily presented themselves for screening. Among these 574 volunteers, 69 (12%) failed the FDT and underwent HFA analysis. Eighty-one per cent (56/69) of these FDT failures had abnormal HFA Glaucoma Hemifield Tests, Eighty-eight per cent (61/69) were judged to have nerve fibre type visual field loss on HFA by at least two of three masked examiners, A positive correlation existed between the number of FDT locations missed and the HFA mean deviation (r = 0.5, P = 0.0001). A similar association was observed when FDT and HFA results were analysed by quadrant (r = 0.5, P < 0.0001). Conclusion: There was a low false positive rate and a good positive predictive value comparing the FDT screening algorithm to the HFA 24-2 SITA-FAST in this study. This supports the potential use of FDT as an economical screening device.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 26 条
[11]   THE EPIDEMIOLOGY OF OPEN-ANGLE GLAUCOMA - A REVIEW [J].
LESKE, MC .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1983, 118 (02) :166-191
[12]  
MADDESS T, 1992, CLIN VISION SCI, V7, P371
[13]  
Mills R. P., 1998, IOVS, V39, pS25
[14]  
*NAT ADV EY COUNC, 1999, VIS RES NAT PLAN 199, P17
[15]   Algorithm for interpreting the results of frequency doubling perimetry [J].
Patel, SC ;
Friedman, DS ;
Varadkar, P ;
Robin, AL .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2000, 129 (03) :323-327
[16]  
Perez J. S., 1998, IOVS, V39, pS26
[17]  
QUIGLEY HA, 1987, INVEST OPHTH VIS SCI, V28, P913
[18]   Identification of glaucoma-related visual field abnormality with the screening protocol of frequency doubling technology [J].
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 125 (06) :819-829
[19]  
QUIGLEY HA, 1988, OPHTHALMOLOGY, V95, P357
[20]   OPTIC-NERVE DAMAGE IN HUMAN GLAUCOMA .3. QUANTITATIVE CORRELATION OF NERVE-FIBER LOSS AND VISUAL-FIELD DEFECT IN GLAUCOMA, ISCHEMIC NEUROPATHY, PAPILLEDEMA, AND TOXIC NEUROPATHY [J].
QUIGLEY, HA ;
ADDICKS, EM ;
GREEN, WR .
ARCHIVES OF OPHTHALMOLOGY, 1982, 100 (01) :135-146