Piroxicam quantitation in human plasma by high-performance liquid chromatography with on- and off-line solid-phase extraction

被引:29
作者
Yritia, M
Parra, P
Fernández, JM
Barbanoj, JM
机构
[1] St Pau Hosp, Inst Res, Anal Lab, Barcelona 08025, Spain
[2] Spark Holland, Amsterdam, Netherlands
[3] St Pau Hosp, Inst Res, Pharmacol Res Area, Barcelona 08025, Spain
关键词
solid-phase extraction; piroxicam;
D O I
10.1016/S0021-9673(99)00515-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A comparative study of two analytical methodologies for piroxicam quantitation in plasma by off-line and on-line solid-phase extraction (SPE) and high-performance liquid chromatography (HPLC) is described. The SPE cartridges contained C-8 for both extraction methods. The analytes piroxicam and tenoxican (internal standard) were separated on a C-18 column with a mobile phase consisting of acetonitrile:20 mM phosphate buffer pH 3.1 (50:50, v/v) followed by UV detection at 360 nm. The validation of the methods demonstrated good recoveries (over 90%), sensitivity (limits of quantification of 0.05 mu g/ml with on-line SPE and 0.1 mu g/ml with off-line SPE, based on a 100 mu l and 200 mu l sample volume, respectively), accuracy and precision (better than 9.5%). Both methodologies have been used for bioequivalence studies. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:199 / 205
页数:7
相关论文
共 23 条
  • [1] AGVERINOS A, 1995, J CHROMATOGR B, V673, P142
  • [2] Rapid method for the determination of piroxicam in rat plasma using high-performance liquid chromatography
    Amanlou, M
    Dehpour, AR
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 696 (02): : 317 - 319
  • [3] Stereoselective interaction between piroxicam and acenocoumarol
    Bonnabry, P
    Desmeules, J
    Rudaz, S
    Leemann, T
    Veuthey, JL
    Dayer, P
    [J]. BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1996, 41 (06) : 525 - 530
  • [4] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR PIROXICAM IN HUMAN-PLASMA
    BOUDINOT, FD
    IBRAHIM, SS
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 430 (02): : 424 - 428
  • [5] PIROXICAM - A REAPPRAISAL OF ITS PHARMACOLOGY AND THERAPEUTIC EFFICACY
    BROGDEN, RN
    HEEL, RC
    SPEIGHT, TM
    AVERY, GS
    [J]. DRUGS, 1984, 28 (04) : 292 - 323
  • [6] RAPID AND SENSITIVE DETERMINATION OF PIROXICAM IN RAT PLASMA, MUSCLE AND SKIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CERRETANI, D
    MICHELI, L
    FIASCHI, AI
    GIORGI, G
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 614 (01): : 103 - 108
  • [7] RAPID METHOD FOR THE DETERMINATION OF EITHER PIROXICAM OR TENOXICAM IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DIXON, JS
    LOWE, JR
    GALLOWAY, DB
    [J]. JOURNAL OF CHROMATOGRAPHY, 1984, 310 (02): : 455 - 459
  • [8] A REPRODUCIBLE AND RAPID HPLC ASSAY FOR QUANTITATION OF PIROXICAM IN PLASMA
    EDNO, L
    BRESSOLLE, F
    COMBE, B
    GALTIER, M
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (06) : 785 - 789
  • [9] RAPID ANALYSIS OF PIROXICAM IN DOG, RAT AND HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    GILLILAN, RB
    MASON, WD
    FU, CHJ
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 487 (01): : 232 - 235
  • [10] DETERMINATION OF TENOXICAM IN HUMAN-PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HEIZMANN, P
    KORNER, J
    ZINAPOLD, K
    [J]. JOURNAL OF CHROMATOGRAPHY, 1986, 374 (01): : 95 - 102