A Closed-Tube Detection of Loop-Mediated Isothermal Amplification (LAMP) Products Using a Wax-Sealed Fluorescent Intercalator

被引:27
作者
Liang, Chao [1 ]
Chen, Sijia [1 ]
Chu, Yanan [1 ]
Wu, Haiping [2 ]
Zou, Binjie [3 ]
Huang, Huan [2 ]
Xi, Tao [1 ]
Zhou, Guohua [1 ,2 ,3 ]
机构
[1] China Pharmaceut Univ, Coll Life Sci & Technol, Nanjing 210009, Jiangsu, Peoples R China
[2] Huadong Res Inst Med & Biotech, Nanjing 210002, Jiangsu, Peoples R China
[3] Nanjing Univ, Jinling Hosp, Dept Pharmacol, Sch Med, Nanjing 210002, Jiangsu, Peoples R China
关键词
Loop Mediated Isothermal Amplification; Wax-Sealed; SYBR Green I; Visible Detection; Pathogen Detection;
D O I
10.1166/jnn.2013.6497
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
LAMP is an isothermal amplification method that can achieve ultra-high sensitivity and specificity. However, the conventional detection of LAMP amplicons can lead to cross-contamination due to the need to open the reaction tube which contains a large number of amplicons. To achieve closed-tube LAMP detection, we have developed a method that separates a solution of SYBR Green I (SGI) from the LAMP reagents using temperature-sensitive wax. The SGI is sealed in the bottom of the tube so not to interfere with the LAMP reaction, but is released into the mixture after the completion of the reaction by melting the wax. To enable the analysis of the closed-tube LAMP samples automatically, an instrument based on this new method was constructed. The background measurement of the LAMP due to primer dimers was significantly reduced by detecting the amplicons at 75 degrees C. HBV and 2009 H1N1 virus were successfully analyzed by the LAMP assay using tubes containing wax-sealed SGI and the prototype instrument, indicating that the method has the advantage of easy set-up (no extra components need to be added into the LAMP mixture for detection), high sensitivity (fluorescent intercalator), low background (detected at 75 degrees C) and no cross-contamination (closed-tube). Therefore, the novel LAMP detection, coupled with the instrument has the potential to be a diagnostic tool for a number of clinical applications in hospitals as well as on-site screening of pathogenic agents.
引用
收藏
页码:3999 / 4005
页数:7
相关论文
共 26 条
[1]   Discrimination of Single Nucleotide Mutation by Using a New Class of Immobilized Shared-Stem Double-Stranded DNA Probes [J].
Bai, Yunfei ;
Lin, Dai ;
Han, Qin ;
Jia, Yaojuan ;
Tu, Jing ;
Luo, Junfeng ;
Ge, Qinyu ;
Zhang, Dingdong ;
Lu, Zuhong .
JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2011, 7 (05) :640-647
[2]   Emergence of a Novel Swine-Origin Influenza A (H1N1) Virus in Humans Novel Swine-Origin Influenza A (H1N1) Virus Investigation Team [J].
Dawood, Fatimah S. ;
Jain, Seema ;
Finelli, Lyn ;
Shaw, Michael W. ;
Lindstrom, Stephen ;
Garten, Rebecca J. ;
Gubareva, Larisa V. ;
Xu, Xiyan ;
Bridges, Carolyn B. ;
Uyeki, Timothy M. .
NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (25) :2605-2615
[3]   Real-time PCR in clinical microbiology: Applications for a routine laboratory testing [J].
Espy, MJ ;
Uhl, JR ;
Sloan, LM ;
Buckwalter, SP ;
Jones, MF ;
Vetter, EA ;
Yao, JDC ;
Wengenack, NL ;
Rosenblatt, JE ;
Cockerill, FR ;
Smith, TF .
CLINICAL MICROBIOLOGY REVIEWS, 2006, 19 (01) :165-+
[4]   Comparison of the Efficacies of Loop-Mediated Isothermal Amplification, Fluorescence Smear Microscopy and Culture for the Diagnosis of Tuberculosis [J].
George, Geojith ;
Mony, Prem ;
Kenneth, John .
PLOS ONE, 2011, 6 (06)
[5]   Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxy naphthol blue [J].
Goto, Motoki ;
Honda, Eiichi ;
Ogura, Atsuo ;
Nomoto, Akio ;
Hanaki, Ken-Ichi .
BIOTECHNIQUES, 2009, 46 (03) :167-+
[6]   Preparation of SiO2/(PMMA/Fe3O4) Nanoparticles Using Linolenic Acid as Cross link Agent for Nucleic Acid Detection Using Chemiluminescent Method [J].
He, Lei ;
Li, Zhiyang ;
Fu, Jing ;
Wang, Fang ;
Ma, Chao ;
Deng, Yan ;
Shi, Zhiyang ;
Wang, Hua ;
He, Nongyue .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (03) :2256-2262
[7]   Loop-mediated isothermal amplification for influenza A (H5N1) virus [J].
Jayawardena, Shanthi ;
Cheung, Chung Y. ;
Barr, Ian ;
Chan, Kwok H. ;
Chen, Honglin ;
Guan, Yi ;
Peiris, J. S. Malik ;
Poon, Leo L. M. .
EMERGING INFECTIOUS DISEASES, 2007, 13 (06) :899-901
[8]   Polymerase Chain Reaction Coupling with Magnetic Nanoparticles-Based Biotin-Avidin System for Amplification of Chemiluminescent Detection Signals of Nucleic Acid [J].
Li, Zhiyang ;
He, Lei ;
He, Nongyue ;
Deng, Yan ;
Shi, Zhiyang ;
Wang, Hua ;
Li, Song ;
Liu, Hongna ;
Wang, Zhifei ;
Wang, Daxin .
JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2011, 11 (02) :1074-1078
[9]  
LIU H, J NANOSCI NANOTECHNO
[10]   An integrated and sensitive detection platform for biosensing application based on Fe@Au magnetic nanoparticles as bead array carries [J].
Liu, Hongna ;
Li, Song ;
Liu, Lishang ;
Tian, Lan ;
He, Nongyue .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (04) :1442-1448