Portable device for continuous fractionated blood sampling and continuous ex vivo blood glucose monitoring

被引:12
作者
Trajanoski, Z
Wach, P
Gfrerer, R
Jobst, G
Urban, G
Kotanko, P
Skrabal, F
机构
[1] VIENNA TECH UNIV,INST ALLGEMEINE ELEKTROTECH & ELEKTRON,A-1040 VIENNA,AUSTRIA
[2] KRANKENHAUS BARMHERZIGEN BRUDER,DEPT INTERNAL MED,A-8020 GRAZ,AUSTRIA
关键词
Biochemical monitoring; Blood glucose; Glucose sensors; Measurement;
D O I
10.1016/0956-5663(96)86784-4
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The objective of the study was to develop and evaluate a portable device for continuous fractionated blood sampling and continuous ex vivo monitoring of blood glucose. The inner lumen of a double lumen catheter (18 gauge x 45 mm) was placed in a peripheral vein and perfused with heparin solution (1.4 U min(-1)). The outer lumen was used to collect heparinized blood into 48 vacuum tubes at programmable sample volumes and time intervals (0.2-2 ml in 2.5-30 min). A sensor flow chamber with an internal volume of 1 mm(3) incorporating a miniaturized thin-film amperometric glucose sensor was placed in the sampling line for continuous ex vivo blood glucose monitoring. Blood glucose and plasma insulin were measured during a frequently sampled intravenous glucose tolerance test (250 mg kg(-1)) and a subsequent oral glucose tolerance test (150 g) over 6 h in eight healthy volunteers (BMI 24.5 +/- 3.2 kg m(-2)). Additionally, in four experiments blood glucose was measured on-line using the glucose sensors. The overall correlation coefficients for whole blood glucose and plasma insulin between the manually drawn samples and the vacuum tubes were 0.73 and 0.87, respectively (p < 0.001). The miniaturized glucose sensor exhibited a linear measuring range of 25 mmol(-1) glucose concentration and 95% response times of less than 30 s. Sensor readings and laboratory analyser results for the blood glucose measurement correlated between 0.93 and 0.98 (p < 0.001). In summary, continuous fractionated blood sampling and ex vivo blood glucose monitoring in ambulatory subjects is possible with a portable device.
引用
收藏
页码:479 / 487
页数:9
相关论文
共 9 条
[1]  
ALBISSER AM, 1974, DIABETES, V23, P289
[2]   PROGRESS IN PRACTICAL ENDOCRINOLOGY - THE GLUCOSENSOR UNITEC ULM - A PORTABLE MONITOR FOR CONTINUOUS BLOOD-GLUCOSE MEASUREMENT [J].
BRUCKEL, J ;
ZIER, H ;
KERNER, W ;
PFEIFFER, EF .
HORMONE AND METABOLIC RESEARCH, 1990, 22 (07) :382-384
[3]  
CLARKE WL, 1984, DIABETES CARE, V5, P622
[4]  
EISENTRAUT AM, 1968, AM J MED SCI, V255, P137
[5]   DEVELOPMENT OF A MINIATURIZED GLUCOSE MONITORING-SYSTEM BY COMBINING A NEEDLE-TYPE GLUCOSE SENSOR WITH MICRODIALYSIS SAMPLING METHOD - LONG-TERM SUBCUTANEOUS TISSUE GLUCOSE MONITORING IN AMBULATORY DIABETIC-PATIENTS [J].
HASHIGUCHI, Y ;
UEMURA, T ;
SAKAKIDA, M ;
KAJIWARA, K ;
NISHIDA, K ;
SHICHIRI, M .
DIABETES CARE, 1994, 17 (05) :387-396
[6]   MINIATURIZED MULTIENZYME BIOSENSORS INTEGRATED WITH PH SENSORS ON FLEXIBLE POLYMER CARRIERS FOR INVIVO APPLICATIONS [J].
URBAN, G ;
JOBST, G ;
KEPLINGER, F ;
ASCHAUER, E ;
TILADO, O ;
FASCHING, R ;
KOHL, F .
BIOSENSORS & BIOELECTRONICS, 1992, 7 (10) :733-739
[7]  
Urban G, 1994, Technol Health Care, V1, P215, DOI 10.3233/THC-1994-1304
[8]   MINIMAL MODEL ANALYSIS OF INTRAVENOUS GLUCOSE-TOLERANCE TEST-DERIVED INSULIN SENSITIVITY IN DIABETIC SUBJECTS [J].
WELCH, S ;
GEBHART, SSP ;
BERGMAN, RN ;
PHILLIPS, LS .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1990, 71 (06) :1508-1518
[9]   INTERFERENCE OF HEMOLYSIS ON RADIOIMMUNOASSAY OF INSULIN AND ITS PREVENTION BY PRE-INCUBATION WITH ANTI-INSULIN SERUM [J].
ZIEGLER, M ;
KLATT, D ;
HOMMEL, H ;
MICHAEL, R .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1972, 35 (02) :317-+