Studies of proximity focusing RICH with an aerogel radiator using flat-panel multi-anode PMTs (Hamamatsu H8500)

被引:49
作者
Matsumoto, T
Korpar, S
Adachi, I
Fratina, S
Iijima, T
Ishibashi, R
Kawai, H
Krizan, P
Ogawa, S
Pestotnik, R
Saitoh, S
Seki, T
Sumiyoshi, T
Suzuki, K
Tabata, T
Uchida, Y
Unno, Y
机构
[1] Tokyo Metropolitan Univ, Dept Phys, Hachioji, Tokyo, Japan
[2] Jozef Stefan Inst, Ljubljana, Slovenia
[3] KEK, High Energy Accelerator Res Organizat, Tsukuba, Ibaraki, Japan
[4] Nagoya Univ, Nagoya, Aichi, Japan
[5] Chiba Univ, Chiba, Japan
[6] Toho Univ, Funabashi, Chiba 274, Japan
基金
日本学术振兴会;
关键词
aerogel; flat-panel PMT; ring imaging Cherenkov counter; proximity focusing; particle identification; Belle;
D O I
10.1016/j.nima.2003.11.384
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A proximity focusing ring imaging Cherenkov detector using aerogel as the radiator has been studied for upgrading the Belle detector at the KEK-B-factory. We constructed a prototype Cherenkov counter using a 4 x 4 array of 64-channel flat-panel multi-anode PMTs (Hamamatsu H8500) with a large effective area. The aerogel samples were made with a new technique to obtain a higher transmission length at a high refractive index (n = 1.05). Multi-channel PMTs are read-out with analog memory chips. The detector was tested at the KEK-PS pi2 beam line in November, 2002. To evaluate systematically the performance of the detector, tests were carried out with various aerogel samples using pion beams with momenta between 0.5 and 4 GeV/c. The typical angular resolution was around 14 mrad, and the average number of detected photoelectrons was around 6. We expect that pions and kaons can be separated at a 4sigma level at 4 GeV/c. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 377
页数:11
相关论文
共 14 条
[1]   The Belle detector [J].
Abashian, A ;
Abe, K ;
Abe, R ;
Abe, K ;
Adachi, I ;
Ahn, BS ;
Ahn, HS ;
Aihara, H ;
Akatsu, M ;
Akhmetshin, R ;
Alexander, JP ;
Alimonti, G ;
An, Q ;
Aoki, K ;
Asai, M ;
Asano, Y ;
Aso, T ;
Aulchenko, V ;
Bakich, AM ;
Banas, E ;
Behari, S ;
Behera, PK ;
Beiline, D ;
Bondar, A ;
Bozek, A ;
Browder, TE ;
Casey, BCK ;
Chang, P ;
Chang, YH ;
Chao, Y ;
Chen, HS ;
Chen, HF ;
Chen, YQ ;
Cheon, BG ;
Chidzik, S ;
Choi, S ;
Choi, Y ;
Dneprovsky, L ;
Doi, Y ;
Dong, LY ;
Dragic, J ;
Drutskoy, A ;
Eidelman, S ;
Enomoto, R ;
Everton, CW ;
Fang, F ;
Fujii, H ;
Fujimoto, K ;
Fujita, Y ;
Fukunaga, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (01) :117-232
[2]   STUDY OF A THRESHOLD CHERENKOV COUNTER BASED ON SILICA AEROGELS WITH LOW REFRACTIVE-INDEXES [J].
ADACHI, I ;
SUMIYOSHI, T ;
HAYASHI, K ;
IIDA, N ;
ENOMOTO, R ;
TSUKADA, K ;
SUDA, R ;
MATSUMOTO, S ;
NATORI, K ;
YOKOYAMA, M ;
YOKOGAWA, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 355 (2-3) :390-398
[3]  
ADACHI I, 2002, P IEEE NUCL SCI S NO
[4]   The HERMES dual-radiator ring imaging Cherenkov detector [J].
Akopov, N ;
Aschenauer, EC ;
Bailey, K ;
Bernreuther, K ;
Bianchi, N ;
Capitani, GP ;
Carter, P ;
Cisbani, E ;
De Leo, R ;
De Sanctis, E ;
De Schepper, D ;
Djordjadze, V ;
Filippone, BW ;
Frullani, S ;
Garibaldi, F ;
Hansen, JO ;
Hommez, B ;
Iodice, M ;
Jackson, HE ;
Jung, P ;
Kaiser, R ;
Kanesaka, J ;
Kowalczyk, R ;
Lagamba, L ;
Maas, A ;
Muccifora, V ;
Nappi, E ;
Negodaeva, K ;
Nowak, WD ;
O'Connor, T ;
O'Neill, TG ;
Potterveld, DH ;
Ryckbosch, D ;
Sakemi, Y ;
Sato, F ;
Schwind, A ;
Shibata, TA ;
Suetsugu, K ;
Thomas, E ;
Tytgat, M ;
Urciuoli, GM ;
Van de Kerckhove, K ;
Van de Vyver, R ;
Yoneyama, S ;
Zohrabian, H ;
Zhang, LF .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 479 (2-3) :511-530
[5]   Measurement of optical parameters of aerogel [J].
Buzykaev, AR ;
Danilyuk, AF ;
Ganzhur, SF ;
Kravchenko, EA ;
Onuchin, AP .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 433 (1-2) :396-400
[6]   SILICA AEROGELS USED AS CHERENKOV RADIATORS [J].
CANTIN, M ;
CASSE, M ;
KOCH, L ;
JOUAN, R ;
MESTREAU, P ;
ROUSSEL, D ;
BONNIN, F ;
MOUTEL, J ;
TEICHNER, SJ .
NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (01) :177-182
[7]   Electronic detection of focused Cherenkov rings from aerogel [J].
De Leo, R ;
Lagamba, L ;
Manzari, V ;
Nappi, E ;
Scognetti, T ;
Alemi, M ;
Becker, H ;
Forty, R ;
Adachi, I ;
Suda, R ;
Sumiyoshi, T ;
Perrino, R ;
Matteuzzi, C ;
Seguinot, J ;
Ypsilantis, T ;
Cisbani, E ;
Frullani, S ;
Garibaldi, F ;
Iodice, M ;
Urciuoli, GM .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3) :187-205
[8]   USE OF AEROGEL FOR IMAGING CHERENKOV COUNTERS [J].
FIELDS, DE ;
VANHECKE, H ;
BOISSEVAIN, J ;
JACAK, BV ;
SONDHEIM, WE ;
SULLIVAN, JP ;
WILLIS, WJ ;
WOLF, K ;
NOTEBOOM, E ;
PETERS, PM ;
BURKE, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 349 (2-3) :431-437
[9]   Aerogel Cherenkov counter for the BELLE detector [J].
Iijima, T ;
Adachi, I ;
Enomoto, R ;
Suda, R ;
Sumiyoshi, T ;
Leonidopoulos, C ;
Marlow, DR ;
Prebys, E ;
Kawai, H ;
Kurihara, E ;
Nanao, M ;
Suzuki, K ;
Unno, Y ;
Ogawa, S ;
Murakami, A ;
Khan, MHR .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 453 (1-2) :321-325
[10]  
IIJIMA T, 1997, JPS M TOK METR U SEP