Static and dynamic response of a multiplexed-array piezoresistive contact sensor

被引:33
作者
Otto, JK [1 ]
Brown, TD
Callaghan, JJ
机构
[1] Univ Iowa, Dept Biomed Engn, Biomech Lab, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Orthoped Surg, Iowa City, IA 52242 USA
关键词
piezoresistive; sensor; pressure; stress; drift;
D O I
10.1007/BF02329811
中图分类号
T [工业技术];
学科分类号
08 [工学];
摘要
Multiplexed piezoresistive sensor arrays hold great potential for measuring contact stress distributions for orthopedic research applications. However, their acceptance has been handicapped by output drift and the fact that their dynamic response has not been well characterized. In this report, the static and dynamic responses of one device of this class (the K-Scan piezoresistive contact stress sensor) are formally characterized using a specially made pressure vessel that provides spatially homogeneous contact stress. Drift was predominant early in static loading, reaching relative errors of approximately 30 percent over a 10-min period. During loading, first-order dynamic analysis showed that the time constant land time lag) was nearly zero and there was little attenuation of the output up to 20 Hz. A deconvolution algorithm proved capable of compensating for the great majority of static drift.
引用
收藏
页码:317 / 323
页数:7
相关论文
共 25 条
[1]
DIRECT MEASUREMENT OF LOCAL PRESSURES IN CADAVERIC HUMAN HIP-JOINT [J].
ADAMS, D ;
KEMPSON, GE ;
SWANSON, SAV .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1978, 16 (01) :113-115
[2]
A PRESSURE DISTRIBUTION TRANSDUCER FOR INVITRO STATIC MEASUREMENTS IN SYNOVIAL JOINTS [J].
AHMED, AM .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :309-314
[3]
[Anonymous], P ANN M AM SOC BIOM
[4]
INVITRO MEASUREMENT OF ARTICULAR-CARTILAGE DEFORMATIONS IN THE INTACT HUMAN HIP-JOINT UNDER LOAD [J].
ARMSTRONG, CG ;
BAHRANI, AS ;
GARDNER, DL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1979, 61 (05) :744-755
[5]
STRESS ON THE ARTICULAR SURFACE OF THE HIP-JOINT IN HEALTHY-ADULTS AND PERSONS WITH IDIOPATHIC OSTEOARTHROSIS OF THE HIP-JOINT [J].
BRINCKMANN, P ;
FROBIN, W ;
HIERHOLZER, E .
JOURNAL OF BIOMECHANICS, 1981, 14 (03) :149-156
[6]
BROWN T D, 1984, Journal of Orthopaedic Research, V2, P190, DOI 10.1002/jor.1100020210
[7]
INVITRO CONTACT STRESS DISTRIBUTIONS IN THE NATURAL HUMAN HIP [J].
BROWN, TD ;
SHAW, DT .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :373-384
[8]
A CONTACT-COUPLED FINITE-ELEMENT ANALYSIS OF THE NATURAL ADULT HIP [J].
BROWN, TD ;
DIGIOIA, AM .
JOURNAL OF BIOMECHANICS, 1984, 17 (06) :437-448
[9]
LOOK AT PROSTHESIS-CARTILAGE INTERFACE - DESIGN OF A HIP PROSTHESIS CONTAINING PRESSURE TRANSDUCERS [J].
CARLSON, CE ;
MANN, RW ;
HARRIS, WH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1974, 8 (04) :261-269
[10]
CHOW D, 1995, THESIS U MINN