Characterization of site-specific biomechanical properties of human meniscus-Importance of collagen and fluid on mechanical nonlinearities

被引:86
作者
Danso, E. K. [1 ,2 ]
Makela, J. T. A. [1 ]
Tanska, P. [1 ,2 ]
Mononen, M. E. [1 ]
Honkanen, J. T. J. [1 ,2 ]
Jurvelin, J. S. [1 ]
Toyras, J. [1 ,2 ]
Julkunen, P. [1 ,2 ]
Korhonen, R. K. [1 ,2 ]
机构
[1] Univ Eastern Finland, Dept Appl Phys, FI-70211 Kuopio, Finland
[2] Kuopio Univ Hosp, Diagnost Imaging Ctr, KYS, FI-70029 Kuopio, Finland
基金
欧洲研究理事会;
关键词
Meniscus; Mechanical testing; Fibril reinforced; Poroelastic; Finite element analysis; Stress relaxation; Viscoelastic; Dynamic loading; FINITE-ELEMENT-ANALYSIS; REINFORCED POROELASTIC MODEL; BOVINE ARTICULAR-CARTILAGE; STRESS-RELAXATION RESPONSE; KNEE-JOINT MECHANICS; UNCONFINED COMPRESSION; MEDIAL MENISCUS; PRESSURE DISTRIBUTION; CONFINED COMPRESSION; PARTIAL MENISCECTOMY;
D O I
10.1016/j.jbiomech.2015.01.048
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
Meniscus adapts to joint loads by depth- and site-specific variations in its composition and structure. However, site-specific mechanical characteristics of intact meniscus under compression are poorly known. In particular, mechanical nonlinearities caused by different meniscal constituents (collagen and fluid) are not known. In the current study, in situ indentation testing was conducted to determine site-specific elastic, viscoelastic and poroelastic properties of intact human menisci. Lateral and medial menisci (n=26) were harvested from the left knee joint of 13 human cadavers. Indentation tests, using stress-relaxation and dynamic (sinusoidal) loading protocols, were conducted for menisci at different sites (anterior, middle, posterior, n=78). Sample- and site-specific axisymmetric finite element models with fibril-reinforced poroelastic properties were fitted to the corresponding stress-relaxation curves to determine the mechanical parameters. Elastic moduli, especially the instantaneous and dynamic moduli, showed site-specific variation only in the medial meniscus (p < 0.05 between the sites). The instantaneous and dynamic elastic moduli of the anterior horn were significantly (p < 0.05) greater in the medial than lateral meniscus. The phase angle showed no statistically significant variation between the sites (p > 0.05). The values for the strain-dependent fibril network modulus (nonlinear behaviour of collagen) were significantly different (p < 0.05) between all sites in the medial menisci. Additionally, there was a significant difference (p < 0.01) in the strain-dependent fibril network modulus between the lateral and medial anterior horns. The initial permeability was significantly different (p < 0.05) in the medial meniscus only between the middle and posterior sites. For the strain-dependent permeability coefficient, only anterior and middle sites showed a significant difference (p < 0.05) in the medial meniscus. This parameter demonstrated a significant difference (p < 0.05) between lateral and medial menisci at the anterior horns. Our results reveal that under in situ indentation loading, medial meniscus shows more site-dependent variation in the mechanical properties as compared to lateral meniscus. In particular, anterior horn of medial meniscus was the stiffest and showed the most nonlinear mechanical behaviour. The nonlinearity was related to both collagen fibrils and fluid. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1499 / 1507
页数:9
相关论文
共 61 条
[1]
INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .1. TIBIAL SURFACE OF THE KNEE [J].
AHMED, AM ;
BURKE, DL .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :216-225
[2]
The shocking truth about meniscus [J].
Andrews, Stephen ;
Shrive, Nigel ;
Ronsky, Janet .
JOURNAL OF BIOMECHANICS, 2011, 44 (16) :2737-2740
[3]
Aspden R.M., 1989, MAT PROPERTIES STRES, P109
[4]
ASPDEN RM, 1985, J ANAT, V140, P371
[5]
Dynamic Contact Mechanics of the Medial Meniscus as a Function of Radial Tear, Repair, and Partial Meniscectomy [J].
Bedi, Asheesh ;
Kelly, Natalie H. ;
Baad, Michael ;
Fox, Alice J. S. ;
Brophy, Robert H. ;
Warren, Russell F. ;
Maher, Suzanne A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (06) :1398-1408
[6]
The clinical importance of meniscal tears demonstrated by magnetic resonance imaging in osteoarthritis of the knee [J].
Bhattacharyya, T ;
Gale, D ;
Dewire, P ;
Totterman, S ;
Gale, ME ;
McLaughlin, S ;
Einhorn, TA ;
Felson, DT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (01) :4-9
[7]
Is it important to secure the hems during lateral meniscal transplantation? A cadaveric study [J].
Chen, MI ;
Branch, TP ;
Hutton, WC .
ARTHROSCOPY, 1996, 12 (02) :174-181
[8]
A transversely isotropic biphasic model for unconfined compression of growth plate and chondroepiphysis [J].
Cohen, B ;
Lai, WM ;
Mow, VC .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (04) :491-496
[9]
Comparison of nonlinear mechanical properties of bovine articular cartilage and meniscus [J].
Danso, E. K. ;
Honkanen, J. T. J. ;
Saarakkala, S. ;
Korhonen, R. K. .
JOURNAL OF BIOMECHANICS, 2014, 47 (01) :200-206
[10]
Biphasic poroviscoelastic simulation of the unconfined compression of articular cartilage: I - Simultaneous prediction of reaction force and lateral displacement [J].
DiSilvestro, MR ;
Zhu, QL ;
Wong, M ;
Jurvelin, JS ;
Suh, JKF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (02) :191-197