A simple system for biofilm potential monitoring in drinking water

被引:5
作者
Delahaye, E
Levi, Y
Leblon, G
Montiel, A
机构
[1] SAGEP Eau Paris, Plate Forme Rech, F-94340 Joinville Le Pont, France
[2] Univ Paris Sud, Fac Pharm, EA 3542, Chatenay Malabry, France
[3] Univ Paris Sud, Inst Genet & Microbiol, Orsay, France
[4] SAGEP EAU Paris, F-75014 Paris, France
关键词
D O I
10.1002/jobm.200510005
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
SAGEP-EAU DE PARIS produces drinking water for the city of Paris (France). In order to supply a high quality water, one of the main SAGEP's concerns is to monitor the Biofilm Formation Potentials of the produced drinking waters. Biofilm incubators were installed at the outlet of three Water Treatment Plants (WTP). These incubators allowed biofilm formation and quantification in terms of Fixed Total Organic Carbon (FTOC), fixed culturable bacteria (HPC-R2A) and fixed total bacteria. During this study, quantitative differences appeared between the biofilms formed at the outlet of the three WTPs, leading to different classifications of the Biofilm Formation Potentials of the three produced waters, depending on the used parameter for biofilms quantification. This observation underlined the necessity of a multi-parametric approach for the study of biofilms. More generally, our results validated the use of these sturdy stainless steel incubators, highly adapted to industrial field conditions, for the monitoring of Biofilm Formation Potentials in drinking water networks.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 22 条
[1]   LIVE/DEAD® BacLight™:: application of a new rapid staining method for direct enumeration of viable and total bacteria in drinking water [J].
Boulos, L ;
Prévost, M ;
Barbeau, B ;
Coallier, J ;
Desjardins, R .
JOURNAL OF MICROBIOLOGICAL METHODS, 1999, 37 (01) :77-86
[2]  
Codony F, 2002, J BASIC MICROB, V42, P311, DOI 10.1002/1521-4028(200210)42:5<311::AID-JOBM311>3.0.CO
[3]  
2-6
[4]  
CRISSOTLARUADE M, 1999, J EUR HYDROL, V30, P201
[5]   An ATP-based method for monitoring the microbiological drinking water quality in a distribution network [J].
Delahaye, E ;
Welté, B ;
Levi, Y ;
Leblon, G ;
Montiel, A .
WATER RESEARCH, 2003, 37 (15) :3689-3696
[6]  
DELAHAYE E, 2005, EUROPEAN J WAT QUALI, V36, P15
[7]  
DELAHAYE E, 2001, P AWWA WAT QUAL TECH
[8]   Recovery of culturability of an HOCl-stressed population of Escherichia coli after incubation in phosphate buffer: Resuscitation or regrowth? [J].
Dukan, S ;
Levi, Y ;
Touati, D .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1997, 63 (11) :4204-4209
[9]   Dynamic modelling of bacterial growth in drinking water networks [J].
Dukan, S ;
Levi, Y ;
Piriou, P ;
Guyon, F ;
Villon, P .
WATER RESEARCH, 1996, 30 (09) :1991-2002
[10]  
KAPRELYANTS AS, 1993, FEMS MICROBIOL LETT, V104, P271, DOI 10.1111/j.1574-6968.1993.tb05871.x