Measurement of Heart Rate and Respiratory Rate Using a Textile-Based Wearable Device in Heart Failure Patients

被引:17
作者
Chiarugi, F. [1 ,2 ]
Karatzanis, I. [2 ]
Zacharioudakis, G. [2 ]
Meriggi, P. [3 ]
Rizzo, F.
Stratakis, M. [4 ]
Louloudakis, S. [4 ]
Biniaris, C. [5 ]
Valentini, M. [6 ]
Di Rienzo, M. [3 ,7 ]
Parati, G. [6 ,7 ]
机构
[1] Fdn Res & Technol Hellas, Inst Comp Sci, Biomed Informat Lab, POB 1385 N Plastira 100, GR-70013 Iraklion, Crete, Greece
[2] Fdn Res & Technol Hellas, Inst Comp Sci, Iraklion, Greece
[3] Don Carlo Gnochi Fdn, Biomed Technol Dept, Milan, Italy
[4] FORTHnet SA, Iraklion, Greece
[5] Virtual Med World Solut, Romsey, Hants, England
[6] San Luca Hosp, Inst Auxol Italiano, Dept Cardiol, Milan, Italy
[7] Univ Milano Bicocca, Dept Clin Med, Milan, Italy
来源
COMPUTERS IN CARDIOLOGY 2008, VOLS 1 AND 2 | 2008年
关键词
D O I
10.1109/CIC.2008.4749188
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Changes in heart rate (HR) and respiratory rate (RespR) may be used as markers of early decompensation in chronic heart failure (CHF) patients monitored at home. Aiming at improving quality of care and at reducing hospitalization rate and health care costs in CHF, progress in technology has led to the development of small portable and even wearable devices for the acquisition and transmission of relevant vital signs to a remote monitoring centre. This paper describes a signal acquisition and processing system, based on a wearable textile-based device with sensors for the measurement of one-lead ECG and chest movement, and focuses on the algorithms for HR and RespR evaluation. An electronic board collects and transmits these signals to a PDA, which sends them via Wi-Fi to a home gateway where the HR and the RespR time series are produced. The home gateway packs the data with other vital signs collected by using different devices and sends them in XML, format to a central repository where a clinical decision support system can use them for the defection of early decompensation episodes. The system has successfully overcome a preliminary test phase and is ready for more extensive tests in a real clinical environment.
引用
收藏
页码:901 / +
页数:2
相关论文
共 3 条
[1]   Adaptive Threshold QRS Detector with Best Channel Selection Based on a Noise Rating System [J].
Chiarugi, F. ;
Sakkalis, V. ;
Emmanouilidou, D. ;
Krontiris, T. ;
Varanini, M. ;
Tollis, I. .
COMPUTERS IN CARDIOLOGY 2007, VOL 34, 2007, 34 :157-+
[2]  
Di Rienzo M, 2005, COMPUT CARDIOL, V32, P699
[3]   RESPIRATORY RATE - MEASUREMENT OF VARIABILITY OVER TIME AND ACCURACY AT DIFFERENT COUNTING PERIODS [J].
SIMOES, EAF ;
ROARK, R ;
BERMAN, S ;
ESLER, LL ;
MURPHY, J .
ARCHIVES OF DISEASE IN CHILDHOOD, 1991, 66 (10) :1199-1203