Voltammetric determination of paracetamol at C60-modified glassy carbon electrode

被引:226
作者
Goyal, RN [1 ]
Singh, SP [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
fullerene electrode; paracetamol; electrooxidation;
D O I
10.1016/j.electacta.2005.08.036
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Voltammetric determination of paracetamol was carried out at C-60-modified glassy carbon electrode, which showed stable response with enhanced selectivity and sensitivity. Limitations of conventional methods, viz., hydrolysis time and interference were also overstepped. Common biological and chemical interferents do not show significant interference in a wide concentration range. A linear calibration plot having correlation coefficient .985 was obtained in the range 0.05-1.5 mM paracetamol concentration and the sensitivity of the method has been found as 13.04 mu A mM(-1). Sweep rate studies indicated that electrode reaction is followed by follow-up chemical reactions. Method described is rapid and has been applied for the determination of paracetamol in different tablets and urine samples with several advantages over other analytical methods. The standard deviation (S.D.) was 5.53% for eight determinations. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3008 / 3012
页数:5
相关论文
共 26 条
[1]  
CAMPANELLA L, 1992, B ELECTROCHEM, V8, P229
[2]  
Christian G.D., 1962, JELECTROANAL CHEM, V3, P363, DOI [10.1016/0022-0728(62)80012-6, DOI 10.1016/0022-0728(62)80012-6]
[3]   Fast urinary screening for paracetamol using on-line microwave assisted hydrolysis and spectrophotometric detection [J].
Criado, A ;
Cárdenas, S ;
Gallego, M ;
Valcárcel, M .
ANALYST, 2000, 125 (06) :1179-1183
[4]   Electrochemical reactions of cytochrome c on electrodes modified by fullerene films [J].
Csiszár, M ;
Szúcs, A ;
Tölgyesi, M ;
Mechler, A ;
Nagy, JB ;
Novák, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 497 (1-2) :69-74
[5]   Bioequivalence study of paracetamol tablets:: In vitro-in vivo correlation [J].
Domínguez, A ;
Medina, R ;
Hurtado, M .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2000, 26 (08) :821-828
[6]   CARBON-PASTE ELECTRODES MODIFIED WITH ENZYMES, TISSUES, AND CELLS [J].
GORTON, L .
ELECTROANALYSIS, 1995, 7 (01) :23-45
[7]  
HEKIMOGLU S, 1987, INT J CLIN PHARM TH, V25, P93
[8]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS [J].
KALCHER, K .
ELECTROANALYSIS, 1990, 2 (06) :419-433
[9]   SENSORS BASED ON CARBON-PASTE IN ELECTROCHEMICAL ANALYSIS - A REVIEW WITH PARTICULAR EMPHASIS ON THE PERIOD 1990-1993 [J].
KALCHER, K ;
KAUFFMANN, JM ;
WANG, J ;
SVANCARA, I ;
VYTRAS, K ;
NEUHOLD, C ;
YANG, Z .
ELECTROANALYSIS, 1995, 7 (01) :5-22
[10]  
KALCHER K, 1997, SCI PAP U PARDUBIC A, V3, P57