Gentamicin concentrations in diagnostic aspirates from 25 patients with hip and knee arthroplasties

被引:16
作者
Fletcher, MDA [1 ]
Spencer, RF [1 ]
Langkamer, VG [1 ]
Lovering, AM [1 ]
机构
[1] Southmead Gen Hosp, Avon Orthopaed Ctr, Bristol, Avon, England
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2004年 / 75卷 / 02期
关键词
D O I
10.1080/00016470412331294425
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background There is little information on long-term release of antibiotics from impregnated bone cement. Patients and methods We assayed joint fluids obtained for diagnostic purposes from 25 Patients for the presence of gentamicin. All patients had presented with failing or painful joints up to 20 years following primary hip or knee arthroplasty, using gentamicin-impregnated cement. Results Gentamicin was detected in the joint fluids from 9 of 15 patients with knee prostheses and 4 of 10 patients with hip prostheses. The concentrations ranged from 0.06 mg/L to 0.85 mg/L with no significant differences in concentration between the patients with hip or knee prostheses, or the type of prosthesis. We found no relationship between the gentamicin concentration and the time after primary arthroplasty. Interpretation Although most concentrations were below the levels required to inhibit susceptible pathogens, we conclude that gentamicin release around failing implants may lead to false negative cultures in some patients and provide selective pressure for the emergence of resistance where infection is present in others.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 7 条
[1]
Armstrong M, 2002, Hip Int, V12, P23, DOI 10.5301/HIP.2008.2065
[2]
DEEP INFECTION OF CEMENTED TOTAL HIP ARTHROPLASTIES CAUSED BY COAGULASE-NEGATIVE STAPHYLOCOCCI [J].
HOPE, PG ;
KRISTINSSON, KG ;
NORMAN, P ;
ELSON, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1989, 71 (05) :851-855
[3]
MALCHAU H, 1998, 65 ANN M AM AC ORTH
[4]
The in vitro elution characteristics of antibiotic-loaded CMW and Palacos-R bone cements [J].
Penner, MJ ;
Duncan, CP ;
Masri, BA .
JOURNAL OF ARTHROPLASTY, 1999, 14 (02) :209-214
[5]
PHILLIPS I, 1991, J ANTIMICROB CHEM SD, V27, P50
[6]
Gentamicin release from old cement during revision hip arthroplasty [J].
Powles, JW ;
Spencer, RF ;
Lovering, AM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (04) :607-610
[7]
ASSAY OF LOW TROUGH SERUM GENTAMICIN CONCENTRATIONS BY FLUORESCENCE POLARIZATION IMMUNOASSAY [J].
WHITE, LO ;
MACGOWAN, AP ;
LOVERING, AM ;
HOLT, HA ;
REEVES, DS ;
RYDER, D .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1994, 33 (05) :1068-1070