Rapid, specific determination of iodine and iodide by combined solid-phase extraction/diffuse reflectance spectroscopy

被引:78
作者
Arena, MP
Porter, MD
Fritz, JS [1 ]
机构
[1] US DOE, Ames Lab, Microanalyt Instrumentat Ctr, Ames, IA 50011 USA
[2] Iowa State Univ Sci & Technol, Dept Chem, Ames, IA 50011 USA
关键词
D O I
10.1021/ac0109366
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, rapid methodology for trace analysis using solid-phase extraction is described. The two-step methodology is based on the concentration of an analyte onto a membrane disk and on the determination by diffuse reflectance spectroscopy of the amount of analyte extracted on the disk surface. This method, which is adaptable to a wide range of analytes, has been used for monitoring ppm levels of iodine and iodide in spacecraft water. Iodine is used as a biocide in spacecraft water. For these determinations, a water sample is passed through a membrane disk by means of a 10-mL syringe that is attached to a disk holder assembly. The disk, which is a polystyrene- divinylbenzene composite, is impregnated with poly(vinylpyrrolidone) (PVP), which exhaustively concentrates iodine as a yellow iodine-PVP complex. The amount of concentrated iodine is then determined in only 2 s by using a hand-held diffuse reflectance spectrometer by comparing the result with a calibration curve based on the Kubelka-Munk function. The same general procedure can be used to determine iodide levels after its facile and exhaustive oxidation to iodine by peroxymonosulfate (i.e., Oxone reagent). For samples containing both analytes, a two-step procedure can be used in which the iodide concentration is calculated from the difference in iodine levels before and after treatment of the sample with peroxymonosulfate. With this methodology, iodine and iodide levels in the 0.1-5.0 ppm range can be determined with a total workup time of similar to60 s with a RSD of similar to6%.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 17 条
[1]  
Amelin VG, 1999, J ANAL CHEM+, V54, P574
[2]   Rapid determination of free active chlorine in water by diffuse reflectance spectroscopy after reaction with polyurethane foams [J].
Dmitrienko, SG ;
Sviridova, OA ;
Pyatkova, LN ;
Zhukova, VA ;
Zolotov, YA .
ANALYTICA CHIMICA ACTA, 2000, 405 (1-2) :231-237
[3]   Solid-phase trapping of solutes for further chromatographic or electrophoretic analysis [J].
Fritz, JS ;
Macka, M .
JOURNAL OF CHROMATOGRAPHY A, 2000, 902 (01) :137-166
[4]  
FRITZ JS, 1999, ANAL SOLID PHASE EXT
[5]   Preconcentration of noble metals on a polymer support as complexes of organic reagents and their subsequent determination in the solid phase [J].
Gur'eva, RF ;
Savvin, SB .
JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 55 (03) :249-254
[6]  
Ivanov VM, 1999, J ANAL CHEM+, V54, P233
[7]  
KADER A, 1994, B FAC PHARM, V32, P17
[8]   THE IODIDE-IODINE-TRIIODIDE EQUILIBRIUM AND ION ACTIVITY COEFFICIENT RATIOS [J].
KATZIN, LI ;
GEBERT, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1955, 77 (22) :5814-5819
[9]  
Kortum G., 1969, REFLECTANCE SPECTROS, P106
[10]   DETERMINATION OF TRACE AMOUNTS OF PHOSPHATE IN WATER SAMPLES BY ION-EXCHANGE RESIN THIN-LAYER SPECTROPHOTOMETRY [J].
MATSUHISA, K ;
OHZEKI, K .
ANALYST, 1986, 111 (06) :685-689