Effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure

被引:201
作者
Massie, CA
Hart, RW
Peralez, K
Richards, GN
机构
[1] Alexian Brothers Med Ctr, Elk Grove Village, IL USA
[2] Cent DuPage Hosp, Winfield, IL USA
[3] Green Lane Hosp, Resp Serv, Auckland 3, New Zealand
关键词
compliance; continuous positive airway pressure; humidity; nasal symptoms; obstructive sleep apnea;
D O I
10.1378/chest.116.2.403
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To evaluate the effects of humidification on nasal symptoms and compliance in sleep apnea patients using continuous positive airway pressure (CPAP). Design: A randomized, crossover design was employed. Setting:The study was conducted at two suburban community-based hospital sleep laboratories. Patients: Data were collected on 38 obstructive sleep apnea patients (mean age, 44.1 years) in whom CPAP was a novel treatment. Interventions: The interventions were heated humidity, cold passover humidity, and a washout period without humidity. Measurements and results: Patients were titrated with heated humidity or cold passover humidity in the laboratory and subsequently initiated on humidity. Objective compliance, self-report of factors affecting CPAP use, satisfaction with CPAP, feeling upon awakening, and daytime sleepiness were assessed at the completion of each 3-week treatment period and a S-week washout period. Outcome measures were assessed with one-way analysis of variance followed by Scheffe post hoc comparisons. Significant main effects were observed for compliance (F-2,F-37 = 5.2; p = 0.008), satisfaction with CPAP (F-2,F-37 = 4.5; p = 0.01), and feeling refreshed on a awakening (F-2,F-37 = 4.4; p = 0.02). A significant decrease in daytime sleepiness was observed between baseline and each of the conditions (F-3,F-37 = 55.5; p < 0.0001), but Epworth sleepiness scale scores did not differ between conditions (all p values > 0.56). CPAP use with heated humidity (5.52 +/- 2.1 h/night) was greater than CPAP use without humidity(4.93 +/- 2.2 h/night; p = 0.008). Compliance differences were not observed between CPAP use with cold passover humidity and CPAP use without humidity. Patients were more satisfied with CPAP when it was used with heated or cold passover humidity (p less than or equal to 0.05), However, only heated humidity resulted in feeling more refreshed on awakening (p < 0.05). No significant differences were observed among the three groups on the global adverse side effect score (F-2,F-37 = 2.5; p = 0.09). Specific side effects such as dry mouth or throat and dry nose were reported less frequently when CPAP was used with heated humidity compared to CPAP use without humidity (p < 0.001), Conclusions: Compliance with CPAP is enhanced when heated humidification is employed, This is likely due to a reduction in side effects associated with upper airway symptoms and a more refreshed feeling upon awakening. Compliance gains may be realized sooner if patients are started with heated humidity at CPAP initiation.
引用
收藏
页码:403 / 408
页数:6
相关论文
共 22 条
[1]   Compliance with nasal CPAP can be improved by simple interventions [J].
Chervin, RD ;
Theut, S ;
Bassetti, C ;
Aldrich, MS .
SLEEP, 1997, 20 (04) :284-289
[2]   Self-reported use of CPAP and benefits of CPAP therapy - A patient survey [J].
Engleman, HM ;
AsgariJirhandeh, N ;
McLeod, AL ;
Ramsay, CF ;
Deary, IJ ;
Douglas, NJ .
CHEST, 1996, 109 (06) :1470-1476
[3]   CONTINUOUS NASAL POSITIVE AIRWAY PRESSURE WITH A MOUTH LEAK - EFFECT ON NASAL MUCOSAL BLOOD FLUX AND NASAL GEOMETRY [J].
HAYES, MJ ;
MCGREGOR, FB ;
ROBERTS, DN ;
SCHROTER, RC ;
PRIDE, NB .
THORAX, 1995, 50 (11) :1179-1182
[4]   TREATMENT OF OBSTRUCTIVE SLEEP-APNEA WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE - PATIENT COMPLIANCE, PERCEPTION OF BENEFITS, AND SIDE-EFFECTS [J].
HOFFSTEIN, V ;
VINER, S ;
MATEIKA, S ;
CONWAY, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (04) :841-845
[5]   OBJECTIVE MEASUREMENT OF PATTERNS OF NASAL CPAP USE BY PATIENTS WITH OBSTRUCTIVE SLEEP-APNEA [J].
KRIBBS, NB ;
PACK, AI ;
KLINE, LR ;
SMITH, PL ;
SCHWARTZ, AR ;
SCHUBERT, NM ;
REDLINE, S ;
HENRY, JN ;
GETSY, JE ;
DINGES, DF .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04) :887-895
[7]   Group education sessions and compliance with nasal CPAP therapy [J].
Likar, LL ;
Panciera, TM ;
Erickson, AD ;
Rounds, S .
CHEST, 1997, 111 (05) :1273-1277
[8]  
MCNICHOLAS WT, 1982, AM REV RESPIR DIS, V126, P625
[9]   LONG-TERM OUTCOME FOR OBSTRUCTIVE SLEEP-APNEA SYNDROME PATIENTS - MORTALITY [J].
PARTINEN, M ;
JAMIESON, A ;
GUILLEMINAULT, C .
CHEST, 1988, 94 (06) :1200-1204
[10]   SIDE-EFFECTS OF NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE IN SLEEP-APNEA SYNDROME - STUDY OF 193 PATIENTS IN 2 FRENCH SLEEP CENTERS [J].
PEPIN, JL ;
LEGER, P ;
VEALE, D ;
LANGEVIN, B ;
ROBERT, D ;
LEVY, P .
CHEST, 1995, 107 (02) :375-381