Deformation models and correlation analysis in elastography

被引:93
作者
Bilgen, M
Insana, MF
机构
[1] Department of Radiology, University of Kansas Medical Center, Kansas City
关键词
D O I
10.1121/1.414865
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Cross-correlation functions are derived with the purpose of determining how strain inhomogeneities affect the displacement estimates used in ultrasound-based elastography. Variations in the strain profile occur in most imaging situations and are caused by fluctuations in the stress field or elastic modulus of the sample. An analytical framework for developing signal processing strategies in elastography is described, and the Limitations of correlation-based methods for measuring displacements in tissuelike media caused by static compression are emphasized. This paper includes (1) an accurate approximation for an inverse coordinate transformation that relates pre- and postcompression reflectivity profiles of the media, (2) a derivation of the echo-signal cross-correlation function in media with deterministic or stochastic strain profiles; (3) mathematical and graphical descriptions of the consequences that nonuniformities in the strain profile impose upon the uncertainty of displacement estimation; and (4) a demonstration of the advantages of echo signal conditioning and ultrasonic-pulse shaping to reduce the nonstationary effects that attenuate the cross-correlation peak and reduce the signal-to-noise ratio for displacement estimation. (C) 1996 Acoustical Society of America.
引用
收藏
页码:3212 / 3224
页数:13
相关论文
共 32 条
  • [1] QUANTITATIVE TISSUE MOTION ANALYSIS OF DIGITIZED M-MODE IMAGES - GESTATIONAL DIFFERENCES OF FETAL LUNG
    ADLER, RS
    RUBIN, JM
    BLAND, PH
    CARSON, PL
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (06) : 561 - 569
  • [2] [Anonymous], BIOL ENG
  • [3] BERTRAND M, 1989, P IEEE ULTR S, P859
  • [4] REDUCTION OF IMAGE NOISE IN ELASTOGRAPHY
    CESPEDES, I
    OPHIR, J
    [J]. ULTRASONIC IMAGING, 1993, 15 (02) : 89 - 102
  • [5] DETERMINATION OF TISSUE MOTION VELOCITY BY CORRELATION INTERPOLATION OF PULSED ULTRASONIC ECHO SIGNALS
    DEJONG, PGM
    ARTS, T
    HOEKS, APG
    RENEMAN, RS
    [J]. ULTRASONIC IMAGING, 1990, 12 (02) : 84 - 98
  • [6] MEASUREMENT OF SOFT-TISSUE MOTION USING CORRELATION BETWEEN A-SCANS
    DICKINSON, RJ
    HILL, CR
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1982, 8 (03) : 263 - 271
  • [7] Fung Y.C., 1977, 1 COURSE CONTINUUM M
  • [8] ULTRASOUND CONTRAST-DETAIL ANALYSIS - A PRELIMINARY-STUDY IN HUMAN OBSERVER PERFORMANCE
    HALL, TJ
    INSANA, MF
    SOLLER, NM
    HARRISON, LA
    [J]. MEDICAL PHYSICS, 1993, 20 (01) : 117 - 127
  • [9] DESCRIBING SMALL-SCALE STRUCTURE IN RANDOM-MEDIA USING PULSE-ECHO ULTRASOUND
    INSANA, MF
    WAGNER, RF
    BROWN, DG
    HALL, TJ
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 87 (01) : 179 - 192
  • [10] JACKSON VP, 1994, TECHNICAL ASPECTS BR