Real-time spatial compound imaging in breast ultrasound

被引:93
作者
Huber, S
Wagner, M
Medl, M
Czembirek, H
机构
[1] Lainz Hosp, Dept Radiol, A-1130 Vienna, Austria
[2] Lainz Hosp, Dept Gynecol & Obstet, A-1130 Vienna, Austria
关键词
D O I
10.1016/S0301-5629(01)00490-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
To determine the role of real-time spatial compound imaging in breast ultrasound (US), 38 patients with a total of 50 benign changes (fibroadenomas, cysts, lactiferous duct dilatation) underwent both conventional B-mode US and real-time spatial compound imaging under standardized examination settings. Subsequently, images were reviewed independently by three readers experienced in breast US and evaluated according to a multistage scoring system with regard to the presence of artefacts, delineation of boundaries and depiction of internal structures. With significant reader concordance, real-time spatial compound imaging was found to produce speckle reduction with improvement of tissue differentiation, increased conspicuity of low-contrast lesions, enhanced delineation of capsular margins and ducts, and improved depiction of internal architecture of solid lesions, as well as clearer visualization of cystic contents due to clutter reduction. Preservation of central acoustic enhancement and lateral edge shadowing in cysts and fibroadenomas, however, was recorded better in conventional imaging. (C) 2002 World Federation for Ultrasound in Medicine Biology.
引用
收藏
页码:155 / 163
页数:9
相关论文
共 35 条
[1]   The detection of breast microcalcifications with medical ultrasound [J].
Anderson, ME ;
Soo, MS ;
Bentley, RC ;
Trahey, GE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 101 (01) :29-39
[2]   ADAPTIVE FILTERING FOR REDUCTION OF SPECKLE IN ULTRASONIC PULSE-ECHO IMAGES [J].
BAMBER, JC ;
DAFT, C .
ULTRASONICS, 1986, 24 (01) :41-44
[3]  
BAMBER JC, 1987, PATTERN RECOGN, P120
[4]   BREAST SONOGRAPHY [J].
BASSETT, LW ;
KIMMESMITH, C .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (03) :449-455
[5]   COMPOUND SCANNING WITH AN ELECTRICALLY STEERED BEAM [J].
BERSON, M ;
RONCIN, A ;
POURCELOT, L .
ULTRASONIC IMAGING, 1981, 3 (03) :303-308
[6]   SPECKLE IN ULTRASOUND B-MODE SCANS [J].
BURCKHARDT, CB .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1978, 25 (01) :1-6
[7]   A MULTIMODE REAL-TIME SCANNER [J].
CARPENTER, DA ;
DADD, MJ ;
KOSSOFF, G .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1980, 6 (03) :279-284
[8]   VISUAL IMPACT OF ADAPTIVE SPECKLE REDUCTION ON US B-MODE IMAGES [J].
CRAWFORD, DC ;
COSGROVE, DO ;
TOHNO, E ;
SVENSSON, WE ;
ALMURRANI, B ;
BELL, DS ;
STEPNIEWSKA, K ;
BAMBER, JC .
RADIOLOGY, 1992, 183 (02) :555-561
[9]  
Entrekin R., 1999, Medicamundi, V43, P35
[10]  
Fornage Bruno D., 1993, Ultrasound Quarterly, V11, P1, DOI 10.1097/00013644-199300000-00001