Integrated multiple patch-clamp array chip via lateral cell trapping junctions

被引:89
作者
Seo, J [1 ]
Ionescu-Zanetti, C
Diamond, J
Lal, R
Lee, LP
机构
[1] Univ Calif Berkeley, Dept Bioengn, Berkeley Sensor & Actuator Ctr, Berkeley, CA 94720 USA
[2] Univ Calif Santa Barbara, Neurosci Res Inst, Santa Barbara, CA 93106 USA
关键词
D O I
10.1063/1.1650035
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present an integrated multiple patch-clamp array chip by utilizing lateral cell trapping junctions. The intersectional design of a microfluidic network provides multiple cell addressing and manipulation sites for efficient electrophysiological measurements at a number of patch sites. The patch pores consist of openings in the sidewall of a main fluidic channel, and a membrane patch is drawn into a smaller horizontal channel. This device geometry not only minimizes capacitive coupling between the cell reservoir and the patch channel, but also allows simultaneous optical and electrical measurements of ion channel proteins. Evidence of the hydrodynamic placement of mammalian cells at the patch sites as well as measurements of patch sealing resistance is presented. Device fabrication is based on micromolding of polydimethylsiloxane, thus allowing inexpensive mass production of disposable high-throughput biochips. (C) 2004 American Institute of Physics.
引用
收藏
页码:1973 / 1975
页数:3
相关论文
共 9 条
[1]   Activity of single ion channel proteins detected with a planar microstructure [J].
Fertig, N ;
Klau, M ;
George, M ;
Blick, RH ;
Behrends, JC .
APPLIED PHYSICS LETTERS, 2002, 81 (25) :4865-4867
[2]   Whole cell patch clamp recording performed on a planar glass chip [J].
Fertig, N ;
Blick, RH ;
Behrends, JC .
BIOPHYSICAL JOURNAL, 2002, 82 (06) :3056-3062
[3]   Stable integration of isolated cell membrane patches in a nanomachined aperture [J].
Fertig, N ;
Tilke, A ;
Blick, RH ;
Kotthaus, JP ;
Behrends, JC ;
ten Bruggencate, G .
APPLIED PHYSICS LETTERS, 2000, 77 (08) :1218-1220
[4]   Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells [J].
Klemic, KG ;
Klemic, JF ;
Reed, MA ;
Sigworth, FJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :597-604
[5]   Realization of hollow SiO2 micronozzles for electrical measurements on living cells [J].
Lehnert, T ;
Gijs, MAM ;
Netzer, R ;
Bischoff, U .
APPLIED PHYSICS LETTERS, 2002, 81 (26) :5063-5065
[6]   Structure formation at the interface of liquid liquid bilayer in electric field [J].
Lin, ZQ ;
Kerle, T ;
Russell, TP ;
Schäffer, E ;
Steiner, U .
MACROMOLECULES, 2002, 35 (10) :3971-3976
[7]  
SAKMANN B, 1983, SINGLE CHANNEL RECOR
[8]   Patch-clamping of primary cardiac cells with micro-openings in polyimide films [J].
Stett, A ;
Bucher, V ;
Burkhardt, C ;
Weber, U ;
Nisch, W .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (02) :233-240
[9]   Ion-channel assay technologies:: quo vadis? [J].
Xu, J ;
Wang, XB ;
Ensign, B ;
Li, M ;
Wu, L ;
Guia, A ;
Xu, JQ .
DRUG DISCOVERY TODAY, 2001, 6 (24) :1278-1287