Selectivity tuning of serially coupled (S,S) Whelk-O 1 and (R,R) Whelk-O 1 columns in HPLC

被引:15
作者
Dungelová, J [1 ]
Lehotay, J
Krupcik, J
Cizmárik, J
Welsch, T
Armstrong, DW
机构
[1] Slovak Univ Technol Bratislava, Fac Chem Technol, Dept Analyt Chem, Bratislava, Slovakia
[2] Comenius Univ, Fac Pharm, Dept Pharmaceut Chem, Bratislava, Slovakia
[3] Univ Ulm, Dept Analyt & Environm Chem, D-89069 Ulm, Germany
[4] Iowa State Univ, Dept Chem, Ames, IA 50011 USA
关键词
D O I
10.1093/chromsci/42.3.135
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The selectivity tuning of two columns coupled in series is investigated in chiral high-performance liquid chromatography. Two columns with reversal enantioselectivities [(R,R) Whelk-O 1 and (S,S) Whelk-O 1] are coupled in series via a T connector. Selectivity of such a column series is tuned by varying the mobile phase flows in the individual columns. The flow ratio necessary for the required selectivity is calculated on the basis of retention factors measured on the individual columns. The performance of this method for adjusting the required selectivity is studied by the separation of enantiomers of alkoxy substituted esters of phenylcarbamic acid. It is demonstrated that the change of the mobile phase flows in the individual columns enables change in the elution order of enantiomers.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 14 条
[1]   MIXED BONDED PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY .1. SYNTHESIS AND PHYSICOCHEMICAL CHARACTERIZATION [J].
CHARTIER, A ;
GONNET, C ;
MOREL, D ;
ROCCA, JL ;
SERPINET, J .
JOURNAL OF CHROMATOGRAPHY, 1988, 438 (02) :263-271
[2]  
CIZMARIK J, IN PRESS PHARMAZIE
[3]   CHEMICALLY BONDED MULTIFUNCTIONAL STATIONARY PHASES FOR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CROWTHER, JB ;
HARTWICK, RA .
CHROMATOGRAPHIA, 1982, 16 :349-353
[4]   Study of the mechanism of enantioseparation.: IV.: Study of enantioseparation of some derivatives of phenylcarbamic acid using π-complex stationary phase in HPLC [J].
Dungelová, J ;
Lehotay, J ;
Cizmarik, J ;
Armstrong, DW .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2003, 26 (14) :2331-2350
[5]   EVALUATION OF MIXED-MODE STATIONARY PHASES IN LIQUID-CHROMATOGRAPHY FOR THE SEPARATION OF CHARGED AND UNCHARGED OLIGOMER-LIKE MODEL COMPOUNDS [J].
ELEVELD, JT ;
CLAESSENS, HA ;
AMMERDORFFER, JL ;
VANHERK, AM ;
CRAMERS, CA .
JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (02) :211-227
[6]   TANDEM COLUMNS AND MIXED-BED COLUMNS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
ELRASSI, Z ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1986, 359 :255-264
[7]   SELECTIVITY TUNING OF SERIALLY CONNECTED OPEN-TUBULAR (CAPILLARY) COLUMNS IN GAS-CHROMATOGRAPHY .1. FUNDAMENTAL RELATIONSHIPS [J].
HINSHAW, JV ;
ETTRE, LS .
CHROMATOGRAPHIA, 1986, 21 (10) :561-572
[8]  
KROMIDAS S, 1996, PRACTICAL PROBLEM SO, P14
[9]   Computerized optimization of selectivity for direct capillary gas chromatographic multicomponent separations of enantiomers [J].
Krupcik, J ;
Grena, M ;
Spanik, I ;
Benicka, E ;
Hrouzek, J ;
Skacani, I ;
Sandra, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) :253-262
[10]   Selectivity tuning in chiral dual column gas chromatography [J].
Krupcík, J ;
Spánik, I ;
Benická, E ;
Zabka, M ;
Welsch, T ;
Armstrong, DW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (09) :483-488