Indoor and outdoor air quality investigation at six residential buildings in Hong Kong

被引:37
作者
Lee, SC [1 ]
Chang, M [1 ]
Chan, KY [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Environm Engn Unit, Hung Hom, Kowloon, Peoples R China
关键词
D O I
10.1016/S0160-4120(99)00014-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The indoor air quality (IAQ) at six residential buildings in Hong Kong was investigated based on different locations and characteristics. IAQ parameters measured from October 1997 to January 1998 included temperature, relative humidity, CO2, PM10, HCHO, bacteria, SO2, NO, NO2, and CO. CO2, PM10, and HCHO were monitored for a 24-h period, and other IAQ pollutants were monitored continuously. IAQ pollutants at the six sites were below the Hong Kong Interim IAQ Guidelines except for PM10 and bacteria levels. Sites where tobacco smoking is permitted had the worst IAQ. During smoking, PM10 levels were as high as 2153 mu g/m(3). All sites had bacteria levels below the recommended action level of 1000 CFU/m(3). Three sites (North Point, Ngau Tau Kok, and Prince Edward), with relatively high bacteria levels, were buildings over 20 y old. Maximum CO2 levels detected were as high as 2.63 mL/L due to poor ventilation. The results indicated that IAQ at residential areas in Hong Kong should be constantly monitored and improved. (C) 1999 Elsevier Science Ltd.
引用
收藏
页码:489 / 496
页数:8
相关论文
共 9 条
[1]   Indoor air quality in homes, offices and restaurants in Korean urban areas - Indoor/outdoor relationships [J].
Baek, SO ;
Kim, YS ;
Perry, R .
ATMOSPHERIC ENVIRONMENT, 1997, 31 (04) :529-544
[2]  
CHAN DWT, 1995, INDOOR AIR INTEGRATE, P427
[3]  
LARRY CH, 1993, ENVIRON INT, V19, P9
[4]   Indoor/outdoor air quality correlation and questionnaire survey at two staff quarters in Hong Kong [J].
Lee, SC ;
Chan, LY .
ENVIRONMENT INTERNATIONAL, 1998, 24 (07) :729-737
[5]   Comparison of indoor and outdoor air quality at two staff quarters in Hong Kong [J].
Lee, SC .
ENVIRONMENT INTERNATIONAL, 1997, 23 (06) :791-797
[6]  
Montgomery DD., 1989, APPL IND HYG, V4, P17, DOI 10.1080/08828032.1989.10389885
[7]  
PANG SW, 1994, INTERIM AIR QUALITY
[8]  
PANG SW, 1994, TOXIC AIR POLLUTION
[9]  
PERRY R, 1994, INDOOR ENVIRON, V3, P224, DOI 10.1177/1420326X9400300409