Balloon flight background measurement with actively-shielded planar and imaging CZT detectors

被引:11
作者
Bloser, PF [1 ]
Narita, T [1 ]
Jenkins, JA [1 ]
Perrin, M [1 ]
Murray, R [1 ]
Grindlay, JE [1 ]
机构
[1] Max Planck Inst Extraterr Phys, D-85748 Garching, Germany
来源
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII | 2002年 / 4497卷
关键词
CZT; background; shielding; balloon flights; hard X-ray astronomy; instrumentation;
D O I
10.1117/12.454226
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector. referred to as "CZT1," consisted of a 10 mm x 10 mm x 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator in the front, giving a 40 degree field of view and surrounded by plastic scintillator, and a thick BGO crystal in the rear. The second detector, "CZT2," comprised two 10 mm x 10 mm x 5 mm CZT crystals, one made of eV Products high pressure Bridgman material and the other of IMARAD horizontal Bridgman material. each fashioned with a 4 x 4 array of gold pixels on a 2.5 mm pitch. The pixellated detectors were flip-chip-mounted side by side and read out by a 32-channel ASIC. This detector was also shielded by a passive/plastic collimator in the front. but used only additional passive/plastic shielding in the rear. Both experiments were flown from Ft. Sumner, NM on September 19, 2000 on a 24 hour balloon flight. Both instruments performed well. CZT1 recorded a non-vetoed background level at 100 keV of similar to 1 x 10(-3) cts cm(-2) s(-1) keV(-1). Raising the BGO threshold from 50 keV to similar to 1 MeV produced only an 18% increase in this level. CZT2 recorded a background at 100 keV of similar to 4 x 10(-3) cts cm(-2) s(-1) keV(-1) in the eV Products detector and similar to 6 x 10(-3) cts cm(-2) s(-1) keV(-1) in the IMARAD detector, a difference possibly due to our internal background subtracting procedure. Both CZT1 and CZT2 spectra were in basic agreement with Monte Carlo simulations, though both recorded systematically higher count rates at high energy than predicted. No lines were observed, indicating that neutron capture reactions, at least those producing decay lines at a few 100 keV, are not significant components of the CZT background. Comparison of the CZT1 and CZT2 spectra indicates that passive/plastic shielding may provide adequately low background levels for many applications.
引用
收藏
页码:88 / 99
页数:12
相关论文
共 22 条
[1]   CALCULATIONS OF NEUTRON-FLUX SPECTRA INDUCED IN EARTHS ATMOSPHERE BY GALACTIC COSMIC-RAYS [J].
ARMSTRONG, TW ;
CHANDLER, KC ;
BARISH, J .
JOURNAL OF GEOPHYSICAL RESEARCH, 1973, 78 (16) :2715-2726
[2]  
BARTHELMY SD, 2000, P SPIE, V4140
[3]   CdZnTe background measurement at balloon altitudes with an active BGO shield [J].
Bloser, P ;
Grindlay, J ;
Narita, T ;
Harrison, F .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY IX, 1998, 3445 :186-196
[4]  
BLOSER P, 1998, P MRS, V487, P153
[5]   Construction and testing of a pixellated CZT detector and shield for a hard X-ray astronomy balloon flight [J].
Bloser, PF ;
Narita, T ;
Jenkins, JA ;
Grindlay, JE .
X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XI, 2000, 4140 :237-248
[6]   Design and testing of a prototype pixellated CZT detector and shield for hard X-ray astronomy [J].
Bloser, PF ;
Grindlay, JE ;
Narita, T ;
Jenkins, JA .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY X, 1999, 3765 :388-396
[7]   CDTE AND CDZNTE CRYSTAL-GROWTH BY HORIZONTAL BRIDGMAN TECHNIQUE [J].
CHEUVART, P ;
ELHANANI, U ;
SCHNEIDER, D ;
TRIBOULET, R .
JOURNAL OF CRYSTAL GROWTH, 1990, 101 (1-4) :270-274
[9]  
Grindlay J, 2000, AIP CONF PROC, V510, P784
[10]  