Standardized uptake values of fluorine-18 fluorodeoxyglucose: The value of different normalization procedures

被引:60
作者
Schomburg, A
Bender, H
Reichel, C
Sommer, T
Ruhlmann, J
Kozak, B
Biersack, HJ
机构
[1] UNIV BONN,PET CTR BONN,DEPT RADIOL,BONN,GERMANY
[2] UNIV BONN,PET CTR BONN,DEPT INTERNAL MED,BONN,GERMANY
来源
EUROPEAN JOURNAL OF NUCLEAR MEDICINE | 1996年 / 23卷 / 05期
关键词
positron emission tomography; fluorine-18; fluorodeoxyglucose; standardized uptake value; semiquantitation;
D O I
10.1007/BF00833394
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
While the evident advantages of absolute metabolic rate determinations cannot be equalled by static image analysis of fluorine-18 fluorodeoxyglucose positron emission tomographic (FDG PET) studies, various algorithms for the normalization of static FDG uptake values have been proposed. This study was performed to compare different normalization procedures in terms of dependency on individual patient characteristics. Standardized FDG uptake values (SUVs) were calculated for liver and lung tissue in 126 patients studied with whole-body FDG PET. Uptake values were normalized for total body weight, lean body mass and body surface area. Ranges, means, medians, standard deviations and variation coefficients of these SUV parameters were calculated and their interdependency with total body weight, lean body mass, body surface area, patient height and blood sugar levels was calculated by means of regression analysis. Standardized FDG uptake values normalized for body surface area were clearly superior to SUV parameters normalized for total body weight or lean body mass. Variation and correlation coefficients of body surface area-normalized uptake values were minimal when compared with SUV parameters derived from the other normalization procedures. Normalization for total body weight resulted in uptake values still dependent on body weight and blood sugar levels, while normalization for lean body mass did not eliminate the positive correlation with lean body mass and patient height. It is concluded that normalization of FDG uptake values for body surface area is less dependent on the individual patient characteristics than are FDG uptake values normalized for other parameters, and therefore appears to be preferable for FDG PET studies in oncology.
引用
收藏
页码:571 / 574
页数:4
相关论文
共 10 条
[1]  
DAHLBOM M, 1992, J NUCL MED, V33, P1191
[2]  
DICHIRO G, 1988, J NUCL MED, V29, P1603
[3]   PET EVALUATION OF SOFT-TISSUE MASSES WITH F-18 FLUORO-2-DEOXY-D-GLUCOSE [J].
GRIFFETH, LK ;
DEHDASHTI, F ;
MCGUIRE, AH ;
MCGUIRE, DJ ;
PERRY, DJ ;
MOERLEIN, SM ;
SIEGEL, BA .
RADIOLOGY, 1992, 182 (01) :185-194
[4]  
HUBNER KF, 1995, CLIN NUCL MED, V20, P293
[5]  
Kim C. K., 1995, Journal of Nuclear Medicine, V36, p201P
[6]  
KIM CK, 1994, J NUCL MED, V35, P164
[7]  
LESKINENKALLIO S, 1994, J NUCL MED, V35, P1564
[8]  
STRAUSS LG, 1991, J NUCL MED, V32, P623
[9]  
WONG FCL, 1994, J NUCL MED, V35, pP220
[10]   STANDARDIZED UPTAKE VALUES OF NORMAL-TISSUES AT PET WITH 2-[FLUORINE-L8]-FLUORO-2-DEOXY-D-GLUCOSE - VARIATIONS WITH BODY-WEIGHT AND A METHOD FOR CORRECTION [J].
ZASADNY, KR ;
WAHL, RL .
RADIOLOGY, 1993, 189 (03) :847-850