Contrast-enhanced near-infrared laser mammography with a prototype breast scanner - Feasibility study with tissue phantoms and preliminary results of imaging experimental tumors

被引:9
作者
Boehm, T
Hochmuth, A
Malich, A
Reichenbach, JR
Fleck, M
Kaiser, WA
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, Dept Med Radiol, CH-8091 Zurich, Switzerland
[2] Univ Freiburg, Klinikum, Sekt Neuroradiol, Freiburg, Germany
[3] Univ Jena, Inst Diagnost & Intervent Radiol, D-6900 Jena, Germany
关键词
laser mammography; contrast media; animal trials; VX2; tumor;
D O I
10.1097/00004424-200110000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Near-infrared (NIR) optical mammography without contrast has a low specificity. The application of optical contrast medium may improve the performance. The concentration-dependent delectability of a new NIR contrast medium was determined with a prototype optical breast scanner. In vivo imaging of experimental tumors was performed. METHODS. The NIR contrast agent NIR96010 is a newly synthesized, hydrophilic contrast agent for NIR mammography. A concentration-dependent contrast resolution was determined for tissue phantoms consisting of whole milk powder and gelatin. A central part of the phantoms measuring 2 X 2 cm(2) Without contrast was replaced with phantom material containing 1 mu mol/L to 25 nmol/L NIR96010. The composite phantoms were measured with a prototype NIR breast scanner with lasers of lambda (1) = 785 nm and lambda (2) = 850 nm wavelength. Intensity profiles and standard deviations of the transmission signal in areas with and without contrast were determined by linear fit procedures. Signal-to-noise ratios and spatial resolution as a function of contrast concentration were determined. Near-infrared imaging of five tumor-bearing SCID mice (MX1 breast adenocarcinoma, tumor diameter 5-10 mm) was performed before and after intravenous application of 2 mu mol/kg NIR96010. RESULTS. Spectrometry showed an absorption maximum of the contrast agent at 755 nm. No spectral shifts occurred in protein-containing solution. Signal-to-noise ratio in the transmission intensity profiles ranged from 1.1 at 25 nmol/L contrast to 28 at 1 mu mol/L. At concentrations < 40 nmol/L, no differentiation from the background was possible. The transitional area between the contrast-free edge of the phantom and the central contrast-containing part appeared in the profiles as a steep increase with a width of 4.2 +/- 1.8 mm. The experimental tumors were detectable in nonenhanced images as well as contrast-enhanced images, with better delineation after contrast administration. In postcontrast absorption profiles, a 44.1% +/- 11.3% greater absorption increase was seen in tumor tissue compared with normal tissue. CONCLUSIONS. The laser wavelength lambda (1) of the prototype laser mammography device was not situated at maximum absorption of the contrast agent NIR96010 but on the descending shoulder of the absorption spectrum. This implies a 20% signal loss for contrast detection. Despite the nonideal measurement conditions, concentrations as low as 40 nmol/L were detectable in vitro. In vivo, all tumors were detectable in color-coded nonenhanced scans as well as in contrast-enhanced scans, with better delineation after contrast administration.
引用
收藏
页码:573 / 581
页数:9
相关论文
共 14 条
[1]   Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging [J].
Achilefu, S ;
Dorshow, RB ;
Bugaj, JE ;
Rajagopalan, R .
INVESTIGATIVE RADIOLOGY, 2000, 35 (08) :479-485
[2]   CANCER STATISTICS, 1994 [J].
BORING, CC ;
SQUIRES, TS ;
TONG, T ;
MONTGOMERY, S .
CA-A CANCER JOURNAL FOR CLINICIANS, 1994, 44 (01) :7-26
[3]  
Buttner A, 1993, Gynakol Geburtshilfliche Rundsch, V33 Suppl 1, P299
[4]  
Gotz L, 1998, Aktuelle Radiol, V8, P31
[5]   The risk of mammography as reflected by the media [J].
Jung, H .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (04) :335-335
[6]   INDOCYANINE GREEN CLEARANCE AS A TEST FOR HEPATIC FUNCTION [J].
LEEVY, CM ;
SMITH, F ;
LONGUEVILLE, J ;
PAUMGARTNER, G ;
HOWARD, MM .
JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1967, 200 (03) :236-+
[7]   In vivo characterization of tissue efflux rates of cyanine dyes by near-infrared spectroscopy [J].
Licha, K ;
Ntziachristos, V ;
Riefke, B ;
Becker, A ;
Chance, B ;
Semmler, W .
PHOTON PROPAGATION IN TISSUES IV, PROCEEDINGS, 1998, 3566 :126-133
[8]  
LICHA K, 1996, P SOC PHOTO-OPT INST, V3196, P98
[9]  
MILLER BA, 1993, NIH USDHHS NAT CANC, P93
[10]   Contrast agents for optical mammography [J].
Riefke, B ;
Licha, K ;
Semmler, W .
RADIOLOGE, 1997, 37 (09) :749-755