High colonoscopic prevalence of proximal colon serrated polyps in average-risk men and women

被引:143
作者
Kahi, Charles J. [1 ,2 ]
Li, Xiaochun [3 ]
Eckert, George J. [3 ]
Rex, Douglas K. [1 ]
机构
[1] Indiana Univ Sch Med, Dept Med, Div Gastroenterol & Hepatol, Indianapolis, IN 46202 USA
[2] Richard L Roudebush Vet Affairs Med Ctr, Dept Med, Indianapolis, IN 46202 USA
[3] Indiana Univ Sch Med, Div Biostat, Indianapolis, IN 46202 USA
关键词
COLORECTAL-CANCER; ADENOMA DETECTION; PROTECTION; QUALITY; PATHWAY;
D O I
10.1016/j.gie.2011.08.021
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Proximal colon serrated polyps likely contribute to the decreased protection of colonoscopy against right-sided colorectal cancer. Objective: To estimate the prevalence and extrapolated detection rate of proximal serrated polyps at screening colonoscopy. Design: Retrospective study. Patients: The study involved secondary analyses that used two databases. The first includes screening colonoscopies performed by 15 attending gastroenterologists at two academic endoscopy units between 2000 and 2009. The second includes average-risk patients who had previously participated in a randomized trial comparing high-definition chromocolonoscopy and white-light colonoscopy. Main Outcome Measurements: Prevalence of proximal serrated polyps found by the highest-level detectors and proximal serrated polyp detection rates corresponding to adenoma detection rates of 25% in men and 15% in women, respectively. Results: We analyzed 6681 procedures from the first database. Mean (+/- standard deviation) detection rates for adenomas and proximal serrated polyps were 38% +/- 7.8% (range 17%-47%) and 13% +/- 4.8% (1%-18%), respectively. There was a significant correlation between detection rates for adenomas and proximal serrated polyps for men (R = 0.71; P = .003) and women (R = 0.73; P = .002). Adenoma detection rates of 25% for men and 15% for women both corresponded to a detection rate of 4.5% for proximal serrated polyps. The prevalence of proximal serrated polyps found by the highest-level detector was 18%. The corresponding rate derived from the high-definition screening colonoscopy database was 20%. Limitations: Retrospective study. Conclusion: The prevalence of proximal colon serrated polyps in average-risk patients undergoing screening colonoscopy is higher than previously reported. An extrapolated proximal serrated polyp detection rate of 5% is suggested for average-risk men and women. (Gastrointest Endosc 2012;75:515-20.)
引用
收藏
页码:515 / 520
页数:6
相关论文
共 28 条
[1]   A prospective randomised study on narrow-band imaging versus conventional colonoscopy for adenoma detection:: does narrow-band imaging induce a learning effect? [J].
Adler, A. ;
Pohl, H. ;
Papanikolaou, I. S. ;
Abou-Rebyeh, H. ;
Schachschal, G. ;
Veltzke-Schlieker, W. ;
Khalifa, A. C. ;
Setka, E. ;
Koch, M. ;
Wiedenmann, B. ;
Roesch, T. .
GUT, 2008, 57 (01) :59-64
[2]   Colonoscopic withdrawal times and adenoma detection during screening colonoscopy [J].
Barclay, Robert L. ;
Vicari, Joseph J. ;
Doughty, Andrea S. ;
Johanson, John F. ;
Greenlaw, Roger L. .
NEW ENGLAND JOURNAL OF MEDICINE, 2006, 355 (24) :2533-2541
[3]   Analysis of Administrative Data Finds Endoscopist Quality Measures Associated With Postcolonoscopy Colorectal Cancer [J].
Baxter, Nancy N. ;
Sutradhar, Rinku ;
Forbes, Shawn S. ;
Paszat, Lawrence F. ;
Saskin, Refik ;
Rabeneck, Linda .
GASTROENTEROLOGY, 2011, 140 (01) :65-72
[4]   Association of Colonoscopy and Death From Colorectal Cancer [J].
Baxter, Nancy N. ;
Goldwasser, Meredith A. ;
Paszat, Lawrence F. ;
Saskin, Refik ;
Urbach, David R. ;
Rabeneck, Linda .
ANNALS OF INTERNAL MEDICINE, 2009, 150 (01) :1-W1
[5]   Protection From Colorectal Cancer After Colonoscopy A Population-Based, Case-Control Study [J].
Brenner, Hermann ;
Chang-Claude, Jenny ;
Seiler, Christoph M. ;
Rickert, Alexander ;
Hoffmeister, Michael .
ANNALS OF INTERNAL MEDICINE, 2011, 154 (01) :22-U156
[6]   Protection From Right- and Left-Sided Colorectal Neoplasms After Colonoscopy: Population-Based Study [J].
Brenner, Hermann ;
Hoffmeister, Michael ;
Arndt, Volker ;
Stegmaier, Christa ;
Altenhofen, Lutz ;
Haug, Ulrike .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2010, 102 (02) :89-95
[7]   Total colonic dye-spray increases the detection of diminutive adenomas during routine colonoscopy: a randomized controlled trial [J].
Brooker, JC ;
Saunders, BP ;
Shah, SG ;
Thapar, CJ ;
Thomas, HJW ;
Atkin, WS ;
Cardwell, CR ;
Williams, CB .
GASTROINTESTINAL ENDOSCOPY, 2002, 56 (03) :333-338
[8]   Endoscopist can be more powerful than age and male gender in predicting adenoma detection at colonoscopy [J].
Chen, Shawn C. ;
Rex, Douglas K. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2007, 102 (04) :856-861
[9]   A comparative study of standard vs. high definition colonoscopy for adenoma and hyperplastic polyp detection with optimized withdrawal technique [J].
East, J. E. ;
Stavrindis, M. ;
Thomas-Gibson, S. ;
Guenther, T. ;
Tekkis, P. P. ;
Saunders, B. P. .
ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2008, 28 (06) :768-776
[10]   Variation in the Detection of Serrated Polyps in an Average Risk Colorectal Cancer Screening Cohort [J].
Hetzel, Jeremy T. ;
Huang, Christopher S. ;
Coukos, Jennifer A. ;
Omstead, Kelsey ;
Cerda, Sandra R. ;
Yang, Shi ;
O'Brien, Michael J. ;
Farraye, Francis A. .
AMERICAN JOURNAL OF GASTROENTEROLOGY, 2010, 105 (12) :2656-2664