Direct detection of Escherichia coli O157:H7 in unpasteurized apple juice with an evanescent wave biosensor

被引:25
作者
DeMarco, DR
Lim, DV
机构
[1] Univ S Florida, Dept Biol, SCA 110, Tampa, FL 33620 USA
[2] Univ S Florida, Dept Environm & Occupat Hlth, Tampa, FL 33620 USA
关键词
D O I
10.1111/j.1745-4581.2001.tb00250.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An evanescent wave biosensor was used to detect Escherichia coli O157:H7 in unpasteurized apple juice. Light is launched from a 635 nm laser diode into silica or polystyrene optical waveguides, generating an evanescent field which extends from the waveguide surface. Fluorescent molecules within the evanescent field are excited resulting in an emission signal that the biosensor then detects and quantifies. A sandwich immunoassay was performed on the waveguides using cyanine 5 dye-labeled anti-E. coli O157:H7 antibodies for generation of the specific fluorescent signal. The lower limit of detection was between 6.0 x 10(2) and 6.0 x 10(4) CFU/mL with silica waveguides and between 3.2 x 10(2) and 3.2 x 10(4) CFU/mL using polystyrene waveguides. One-hundred percent correct identification of true positive samples occurred at 6.0 x 10(4) and 3.2 x 10(4) CFU/mL for silica and polystyrene waveguides, respectively. Signals from a variety of non-E. coli O157 bacteria, including closely related enterotoxigenic strains of E. coli at concentrations of similar to10(6) CFU/mL, were below the limits of detection. Assays were conducted in near real-time with results obtained within 15 min of sample processing.
引用
收藏
页码:241 / 257
页数:17
相关论文
共 24 条
[1]   A FIBER OPTIC BIOSENSOR - COMBINATION TAPERED FIBERS DESIGNED FOR IMPROVED SIGNAL ACQUISITION [J].
ANDERSON, GP ;
GOLDEN, JP ;
LIGLER, FS .
BIOSENSORS & BIOELECTRONICS, 1993, 8 (05) :249-256
[2]   AN OUTBREAK OF DIARRHEA AND HEMOLYTIC UREMIC SYNDROME FROM ESCHERICHIA-COLI O157-H7 IN FRESH-PRESSED APPLE CIDER [J].
BESSER, RE ;
LETT, SM ;
WEBER, JT ;
DOYLE, MP ;
BARRETT, TJ ;
WELLS, JG ;
GRIFFIN, PM .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1993, 269 (17) :2217-2220
[3]   USE OF THIOL-TERMINAL SILANES AND HETEROBIFUNCTIONAL CROSSLINKERS FOR IMMOBILIZATION OF ANTIBODIES ON SILICA SURFACES [J].
BHATIA, SK ;
SHRIVERLAKE, LC ;
PRIOR, KJ ;
GEORGER, JH ;
CALVERT, JM ;
BREDEHORST, R ;
LIGLER, FS .
ANALYTICAL BIOCHEMISTRY, 1989, 178 (02) :408-413
[4]   DETECTION OF YERSINIA-PESTIS FRACTION-1 ANTIGEN WITH A FIBER OPTIC BIOSENSOR [J].
CAO, LK ;
ANDERSON, GP ;
LIGLER, FS ;
EZZELL, J .
JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) :336-341
[5]  
*CDCP, 1997, MMWR-MORBID MORTAL W, V46, P5
[6]  
Centers for Disease Control and Prevention (CDC), 1996, MMWR Morb Mortal Wkly Rep, V45, P975
[7]   Rapid detection of Escherichia coli O157:H7 in ground beef using a fiber-optic biosensor [J].
DeMarco, DR ;
Saaski, EW ;
McCrae, DA ;
Lim, DV .
JOURNAL OF FOOD PROTECTION, 1999, 62 (07) :711-716
[8]   Use of real-time polymerase chain reaction and molecular beacons for the detection of Escherichia coli O157:H7 [J].
Fortin, NY ;
Mulchandani, A ;
Chen, W .
ANALYTICAL BIOCHEMISTRY, 2001, 289 (02) :281-288
[9]   THE EPIDEMIOLOGY OF INFECTIONS CAUSED BY ESCHERICHIA-COLI O157-H7, OTHER ENTEROHEMORRHAGIC ESCHERICHIA-COLI, AND THE ASSOCIATED HEMOLYTIC UREMIC SYNDROME [J].
GRIFFIN, PM ;
TAUXE, RV .
EPIDEMIOLOGIC REVIEWS, 1991, 13 :60-98
[10]   Detection of endotoxin using an evanescent wave fiber-optic biosensor [J].
James, EA ;
Schmeltzer, K ;
Ligler, FS .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1996, 60 (03) :189-202