Blood flow volume quantification of cerebral ischemia: Comparison of three noninvasive imaging techniques of carotid and vertebral arteries

被引:52
作者
Ho, SSY [1 ]
Chan, YL [1 ]
Yeung, DKW [1 ]
Metreweli, C [1 ]
机构
[1] Prince Wales Hosp, Dept Diagnost Radiol & Organ Imaging, Shatin, Hong Kong, Peoples R China
关键词
D O I
10.2214/ajr.178.3.1780551
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Determination of blood flow volume is useful in assessing ischemic cerebrovascular disease. We compared the blood flow volume measurement of three noninvasive imaging techniques, namely color velocity imaging quantification, spectral Doppler imaging quantification, and MR phase-contrast flow quantification, to see how well the flow values determined. by each technique agreed with one another. SUBJECTS AND METHODS. Flow volume quantification was tested experimentally using a flow simulator and by the three techniques in the vertebral and internal carotid arteries of 40 patients with histories of cerebral ischemia. In the flow simulation study, the flow values in each technique were compared with the phantom flow by the Wilcoxon's signed rank test. In the patient study, the flow values between each paired technique were compared by paired t test. The significance level was taken at p less than 0.05. RESULTS. Flow volumes were measured by color velocity imaging quantification. MR phase-contrast flow quantification agreed with the phantom flow simulation within the tested range, and spectral Doppler imaging quantification values were significantly overestimated. In patients, a large variation of the blood flow volume was obtained between each technique (p < 0.05). Among them, spectral Doppler imaging quantification showed the highest flow values in the vessels (internal carotid arteries, 312.6 mL/min; vertebral arteries, 112.0 mL/ min), followed by color velocity imaging quantification (internal carotid arteries, 216.8 mL/ min; vertebral arteries, 58.1 mL/min) and MR phase-contrast flow quantification (internal carotid arteries, 169.1 mL/min; vertebral arteries, 66.5 mL/min). CONCLUSION. Blood flow volume measurements determined by the three noninvasive imaging techniques on the same vessel can differ widely, and spectral Doppler imaging quantification consistently overestimated the flow volume. It is, therefore, essential that the same technique, preferably color velocity imaging quantification or MR phase-contrast flow quantification, be used for clinical follow-up investigations in the future.
引用
收藏
页码:551 / 556
页数:6
相关论文
共 15 条
[1]   QUANTITATIVE COMMON CAROTID-ARTERY BLOOD-FLOW - PREDICTION OF INTERNAL CAROTID-ARTERY STENOSIS [J].
ACKROYD, N ;
GILL, R ;
GRIFFITHS, K ;
KOSSOFF, G ;
APPLEBERG, M .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (06) :846-853
[2]   TIME DOMAIN FORMULATION OF PULSE-DOPPLER ULTRASOUND AND BLOOD VELOCITY ESTIMATION BY CROSS-CORRELATION [J].
BONNEFOUS, O ;
PESQUE, P .
ULTRASONIC IMAGING, 1986, 8 (02) :73-85
[3]  
DALLACOSTA F, 1987, INT ANGIOL, V6, P371
[4]  
Eicke BM, 1996, NEUROSONOLOGY, P101
[6]   Preferred technique for blood flow volume measurement in cerebrovascular disease [J].
Ho, SSY ;
Metreweli, C .
STROKE, 2000, 31 (06) :1342-1345
[7]  
Knappertz VA, 1996, J NEUROIMAGING, V6, P1
[8]   Vasodilatory responses and magnetic resonance angiography - Extracranial and intracranial intravascular flow data [J].
Levine, RL ;
Turski, PA ;
Turnipseed, WD ;
Dulli, DA ;
Grist, TM .
JOURNAL OF NEUROIMAGING, 1997, 7 (03) :152-158
[9]  
PELC NJ, 1994, MAGN RESON QUART, V10, P125
[10]   Reference values for vertebral artery flow volume by duplex sonography in young and elderly adults [J].
Seidel, E ;
Eicke, BM ;
Tettenborn, B ;
Krummenauer, F .
STROKE, 1999, 30 (12) :2692-2696