Non-destructive, preclinical evaluation of root canal anatomy of human teeth with flat-panel detector volume CT (FD-VCT)

被引:9
作者
Heidrich, G
Hassepass, F
Dullin, C
Attin, T
Grabbe, E
Hannig, C
机构
[1] Univ Klinikum Gottingen, Abt Diagnost Radiol, D-37075 Gottingen, Germany
[2] Univ Klinikum Gottingen, Abt Zahnerhaltung Pravent Zahnheilkunde & Paradon, D-37075 Gottingen, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2005年 / 177卷 / 12期
关键词
anatomy; experimental study; tissue characterization; high-resolution CT; head/neck; mouth;
D O I
10.1055/s-2005-858557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Successful endodontic diagnostics and therapy call for adequate depiction of the root canal anatomy with multimodal diagnostic imaging. The aim of the present study is to evaluate visualization of the endodont with flat-panel detector volume CT (FD-VCT). Materials and Methods: 13 human teeth were examined with the prototype of a FD-VCT. After data acquisition and generation of volume data sets in volume rendering technology (VRT), the findings obtained were compared to conventional X-rays and cross-section preparations of the teeth. Results: The anatomical structures of the endodont such as root canals, side canals and communications between different root canals as well as denticles could be detected precisely with FD-VCT. The length of curved root canals was also determined accurately. The spatial resolution of the system is around 140 pm. Only around 73% of the main root canals detected with FD-VCT and 87% of the roots could be visualized with conventional dental X-rays. None of the side canals, shown with FD-VCT, was detectable on conventional X-rays. In all cases the enamel and dentin of the teeth could be well delineated. No differences in image quality could be discerned between stored and freshly extracted teeth, or between primary and adult teeth. Conclusion: FD-VCT is an innovative diagnostic modality in preclinical and experimental use for non-destructive three-dimensional analysis of teeth. Thanks to the high isotropic spatial resolution compared with conventional X-rays, even the minutest structures, such as side canals, can be detected and evaluated. Potential applications in endodontics include diagnostics and evaluation of all steps of root canal treatment, ranging from trepanation through determination of the length of the root canal to obturation.
引用
收藏
页码:1683 / 1690
页数:8
相关论文
共 18 条
[1]  
Al Shalabi RM, 2000, INT ENDOD J, V33, P405
[2]  
Dowker S E, 1997, Eur J Dent Educ, V1, P61, DOI 10.1111/j.1600-0579.1997.tb00013.x
[3]  
GRESCHUS S, 2005, ROFO FORTSCHR RONTG, V177, P460
[4]  
HEIDRICH G, 2005, ROFO FORTSCHR RONTG, V177, P466
[5]   Efficacy, cleaning ability and safety of different rotary NiTi instruments in root canal retreatment [J].
Hülsmann, M ;
Bluhm, V .
INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (07) :468-476
[6]  
Kalender WA, 2003, RADIOLOGE, V43, P379, DOI 10.1007/s00117-003-0897-4
[7]   Volumetric computed tomography (VCT): a new technology for noninvasive, high-resolution monitoring of tumor angiogenesis [J].
Kiessling, F ;
Greschus, S ;
Lichy, MP ;
Bock, M ;
Fink, C ;
Vosseler, S ;
Moll, J ;
Mueller, MM ;
Fusenig, NE ;
Traupe, H ;
Semmler, W .
NATURE MEDICINE, 2004, 10 (10) :1133-1138
[8]   Flat-panel detector-based computed tomography: Accuracy of experimental growth rate assessment in pulmonary nodules [J].
Marten, K ;
Engelke, C ;
Grabbe, E ;
Rummeny, EJ .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2004, 176 (05) :752-757
[9]   MICROCOMPUTED TOMOGRAPHY - AN ADVANCED SYSTEM FOR DETAILED ENDODONTIC RESEARCH [J].
NIELSEN, RB ;
ALYASSIN, AM ;
PETERS, DD ;
CARNES, DL ;
LANCASTER, J .
JOURNAL OF ENDODONTICS, 1995, 21 (11) :561-568
[10]   Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation [J].
Ning, R ;
Chen, B ;
Yu, RF ;
Conover, D ;
Tang, XY ;
Ning, Y .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :949-963