Vascular Catheters with a Nonleaching Poly-Sulfobetaine Surface Modification Reduce Thrombus Formation and Microbial Attachment

被引:210
作者
Smith, Roger S. [1 ]
Zhang, Zheng [1 ]
Bouchard, Michael [1 ]
Li, Jun [1 ]
Lapp, Heather S. [1 ]
Brotske, Gregory R. [1 ]
Lucchino, David L. [1 ]
Weaver, Douglas [1 ]
Roth, Laurence A. [1 ]
Coury, Arthur [2 ]
Biggerstaff, John [3 ]
Sukavaneshvar, Sivaprasad [4 ]
Langer, Robert [5 ]
Loose, Christopher [1 ]
机构
[1] Semprus BioSci Corp, Cambridge, MA 02139 USA
[2] Coury Consulting Serv, Boston, MA 02116 USA
[3] Univ Tennessee, Ctr Environm Biotechnol, Knoxville, TN 37996 USA
[4] Thrombodyne, Salt Lake City, UT 84103 USA
[5] MIT, Koch Inst Integrat Canc Res, Dept Chem Engn, Cambridge, MA 02139 USA
关键词
CENTRAL VENOUS CATHETERS; BLOOD-STREAM INFECTIONS; PROTEIN ADSORPTION; LABELED PLATELETS; SOLID TUMORS; COMPLICATIONS; THROMBOGENICITY; PREVENTION; RESISTANCE; HYDRATION;
D O I
10.1126/scitranslmed.3004120
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Adherence of proteins, cells, and microorganisms to the surface of venous catheters contributes to catheter occlusion, venous thrombosis, thrombotic embolism, and infections. These complications lengthen hospital stays and increase patient morbidity and mortality. Current technologies for inhibiting these complications are limited in duration of efficacy and may induce adverse side effects. To prevent complications over the life span of a device without using active drugs, we modified a catheter with the nonleaching polymeric sulfobetaine (polySB), which coordinates water molecules to the catheter surface. The modified surface effectively reduced protein, mammalian cell, and microbial attachment in vitro and in vivo. Relative to commercial catheters, polySB-modified catheters exposed to human blood in vitro had a >98% reduction in the attachment and a significant reduction in activation of platelets, lymphocytes, monocytes, and neutrophils. Additionally, the accumulation of thrombotic material on the catheter surface was reduced by >99% even after catheters were exposed to serum in vitro for 60 days. In vivo, in a highly thrombogenic canine model, device- and vessel-associated thrombus was reduced by 99%. In vitro adherence of a broad spectrum of microorganisms was reduced on both the external and the internal surfaces of polySB-modified catheters compared to unmodified catheters. When unmodified and polySB-modified catheters were exposed to the same bacterial challenge and implanted into animals, 50% less inflammation and fewer bacteria were associated with polySB-modified catheters. This nonleaching, polySB-modified catheter could have a major impact on reducing thrombosis and infection, thus improving patient health.
引用
收藏
页数:10
相关论文
共 40 条
[1]  
Bailly AL, 1996, J BIOMED MATER RES, V30, P101, DOI 10.1002/(SICI)1097-4636(199601)30:1<101::AID-JBM13>3.0.CO
[2]  
2-R
[3]   Enumeration of leukocyte infiltration in solid tumors by confocal laser scanning microscopy [J].
Biggerstaff, J. ;
Weidow, B. ;
Amirkhosravi, A. ;
Francis, J. L. .
BMC IMMUNOLOGY, 2006, 7 (1)
[4]   Clinical and economic outcomes in critically ill patients with nosocomial catheter-related bloodstream infections [J].
Blot, SI ;
Depuydt, P ;
Annemans, L ;
Benoit, D ;
Hoste, E ;
de Waele, JJ ;
Decruyenaere, J ;
Vogelaers, D ;
Colardyn, F ;
Vandewoude, KH .
CLINICAL INFECTIOUS DISEASES, 2005, 41 (11) :1591-1598
[5]   Thrombotic and infectious complications of central venous catheters in patients with hematological malignancies [J].
Boersma, R. S. ;
Jie, K. -S. G. ;
Verbon, A. ;
van Pampus, E. C. M. ;
Schouten, H. C. .
ANNALS OF ONCOLOGY, 2008, 19 (03) :433-442
[6]   Methicillin-Resistant Staphylococcus aureus Central Line-Associated Bloodstream Infections in US Intensive Care Units, 1997-2007 [J].
Burton, Deron C. ;
Edwards, Jonathan R. ;
Horan, Teresa C. ;
Jernigan, John A. ;
Fridkin, Scott K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (07) :727-736
[7]   Surveying for surfaces that resist the adsorption of proteins [J].
Chapman, RG ;
Ostuni, E ;
Takayama, S ;
Holmlin, RE ;
Yan, L ;
Whitesides, GM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2000, 122 (34) :8303-8304
[8]   High rate of complications associated with peripherally inserted central venous catheters in patients with solid tumours [J].
Cheong, K ;
Perry, D ;
Karapetis, C ;
Koczwara, B .
INTERNAL MEDICINE JOURNAL, 2004, 34 (05) :234-238
[9]  
CROUZET C, 1976, MAKROMOL CHEM, V177, P145
[10]   COMPARISON OF THROMBOGENICITY OF COMMERCIALLY AVAILABLE CATHETERS [J].
DURST, S ;
LESLIE, J ;
MOORE, R ;
AMPLATZ, K .
RADIOLOGY, 1974, 113 (03) :599-600