Biomechanics of mandibular distractor orientation: An animal model analysis

被引:28
作者
Cope, JB
Samchukov, ML
Cherkashin, AM
Wolford, LM
Franco, P
机构
[1] Baylor Coll Dent, Dept Orthodont, Dallas, TX 75266 USA
[2] Baylor Coll Dent, TAMUS, Dept Biomed Sci, Dallas, TX 75266 USA
[3] Texas Scottish Rite Hosp Children, Res Dept, Dallas, TX 75219 USA
[4] Baylor Coll Dent, TAMUS, Dept Oral & Maxillofacial Surg & Pharmacol, Dallas, TX 75266 USA
关键词
D O I
10.1016/S0278-2391(99)90017-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Previous reports suggest that device orientation may be one of the most important parameters affecting the successful application of osteodistraction. However, only computer models or cadaver mandibles have been used to investigate the biomechanical effects of device orientation during mandibular distraction osteogenesis. Therefore, the purpose of this study was to compare two different device orientations during bilateral mandibular osteodistraction in an animal model. Materials and Methods: Fifteen skeletally mature beagle dogs underwent 10 mm of bilateral mandibular lengthening by intraoral distraction osteogenesis. The dogs were divided into two groups based on the orientation of the distraction device relative to the mandible when viewed occlusally: either parallel to the body of the mandible (group I) or parallel to the axis of distraction (group II). The effects of device orientation during osteodistraction were then analyzed clinically, radiographically, and by dental cast measurements. Results: Distracters oriented parallel to the body of the mandible caused an increase in the anterior width of the proximal mandibular segments. This lateral displacement of the proximal segments led to several clinical complications, including screw fixation failure and bone resorption under the fixation plates. These effects were minimized when the device was oriented parallel to the axis of distraction. Conclusions: Device orientation plays an important role when applying distraction osteogenesis in a clinical setting. Although other intrinsic and extrinsic factors affect the success of osteodistraction, the devices should be oriented parallel to the axis of distraction to minimize adverse biomechanical effects during bilateral mandibular lengthening.
引用
收藏
页码:952 / 962
页数:11
相关论文
共 32 条
[1]  
Anderson WD., 1994, Atlas of canine anatomy
[2]   Mandibular distraction osteogenesis: A historic perspective and future directions [J].
Cope, JB ;
Samchukov, ML ;
Cherkashin, AM .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1999, 115 (04) :448-460
[3]  
COPE JB, 1998, AM ASS ORTH BOOK ABS, V6, P12
[4]   Distraction osteogenesis of costochondral neomandibles: A clinical experience [J].
Corcoran, J ;
Hubli, EH ;
Salyer, KE .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (02) :311-315
[5]   Vector of device placement and trajectory of mandibular distraction [J].
Grayson, BH ;
McCormick, S ;
Santiago, PE ;
McCarthy, JG .
JOURNAL OF CRANIOFACIAL SURGERY, 1997, 8 (06) :473-480
[6]  
GRYSON JA, 1977, ANGLE ORTHOD, V47, P186
[7]  
Guerrero C, 1995, ODONTOL DIA, V11, P116
[8]   Reactive changes in the temporomandibular joint after mandibular midline osteodistraction [J].
Harper, RP ;
Bell, WH ;
Hinton, RJ ;
Browne, R ;
Cherkashin, AM ;
Samchukov, ML .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 1997, 35 (01) :20-25
[9]  
Hass AJ., 1961, Angle Orthod, V31, P73, DOI [10.1043/0003-3219(1961)0312.0.CO
[10]  
2, DOI 10.1043/0003-3219(1961)0312.0.CO