Antimicrobial activity of prosthetic heart valve sewing cuffs coated with minocycline and rifampin

被引:10
作者
Darouiche, RO
Fowler, VG
Adal, K
Kielhofner, M
Mansouri, D
Reller, LB
机构
[1] Baylor Coll Med, Ctr Prostheses Infect, Houston, TX 77030 USA
[2] St Lukes Episcopal Hosp, Vet Affairs Med Ctr, Houston, TX 77030 USA
[3] Cleveland Clin Fdn, Cleveland, OH 44195 USA
[4] Duke Univ, Med Ctr, Durham, NC 27705 USA
关键词
D O I
10.1128/AAC.46.2.543-545.2002
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Prosthetic heart valve sewing cuffs coated with minocycline and rifampin exhibited in vitro zones of inhibition against all 52 tested clinical isolates responsible for prosthetic valve endocarditis. An in vitro elution study of these coated sewing cuffs demonstrated residual zones of inhibition against Staphylococcus epidermidis for at least 4 weeks.
引用
收藏
页码:543 / 545
页数:3
相关论文
共 14 条
[1]  
CALDERWOOD SB, 1986, J THORAC CARDIOV SUR, V92, P776
[2]   Antimicrobial activity and durability of a novel antimicrobial-impregnated bladder catheter [J].
Darouiche, RO ;
Hampel, OZ ;
Boone, TB ;
Raad, II .
INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 1997, 8 (04) :243-247
[3]   A comparison of two antimicrobial-impregnated central venous catheters [J].
Darouiche, RO ;
Raad, II ;
Heard, SO ;
Thornby, JI ;
Wenker, OC ;
Gabrielli, A ;
Berg, J ;
Khardori, N ;
Hanna, H ;
Hachem, R ;
Harris, RL ;
Mayhall, G .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (01) :1-8
[4]  
Darouiche RO, 1998, J HEART VALVE DIS, V7, P639
[5]   INFECTION AFTER CARDIOVASCULAR SURGERY - CLINICAL STUDY INCLUDING EXAMINATION OF ANTIMICROBIAL PROPHYLAXIS [J].
GOODMAN, JS ;
SCHAFFNE.W ;
COLLINS, HA ;
BATTERSB.EJ ;
KOENIG, MG .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 278 (03) :117-&
[6]  
Hyde JAJ, 1998, J HEART VALVE DIS, V7, P316
[7]   PROSTHETIC VALVE ENDOCARDITIS - A CONTINUING CHALLENGE FOR INFECTION CONTROL [J].
KARCHMER, AW .
JOURNAL OF HOSPITAL INFECTION, 1991, 18 :355-366
[8]   The ex vivo antimicrobial activity and colonization rate of two antimicrobial-bonded central venous catheters [J].
Marik, PE ;
Abraham, G ;
Careau, P ;
Varon, J ;
Fromm, RE .
CRITICAL CARE MEDICINE, 1999, 27 (06) :1128-1131
[9]   The broad-spectrum activity and efficacy of catheters coated with minocycline and rifampin [J].
Raad, I ;
Darouiche, R ;
Hachem, R ;
Mansouri, M ;
Bodey, GP .
JOURNAL OF INFECTIOUS DISEASES, 1996, 173 (02) :418-424
[10]   Central venous catheters coated with minocycline and rifampin for the prevention of catheter-related colonization and bloodstream infections - A randomized, double-blind trial [J].
Raad, I ;
Darouiche, R ;
Dupuis, J ;
AbiSaid, D ;
Gabrielli, A ;
Hachem, R ;
Wall, M ;
Harris, R ;
Jones, J ;
Buzaid, A ;
Robertson, C ;
Shenaq, S ;
Curling, P ;
Burke, T ;
Ericsson, C ;
Greenberg, S ;
Hanania, N ;
Yosher, D ;
Gibson, D ;
Reardon, M ;
Reardon, P ;
Darnule, T ;
Mansouri, M ;
Rolston, K ;
Whimbey, E ;
Bivins, C ;
Huaringa, A ;
Price, K ;
Safar, H .
ANNALS OF INTERNAL MEDICINE, 1997, 127 (04) :267-+