Validation of three-dimensional cardiac image integration: Use of integrated CT image into electroanatomic mapping system to perform catheter ablation of atrial fibrillation

被引:121
作者
Kistler, PM
Earley, MJ
Harris, S
Abrams, D
Ellis, S
Sporton, SC
Schilling, RJ [1 ]
机构
[1] St Bartholomews Hosp, Dept Cardiol, London EC1A 7BE, England
[2] St Bartholomews Hosp, Dept Radiol, London EC1A 7BE, England
[3] Queen Mary Univ, London, England
关键词
ablation; anatomy; atrial fibrillation; imaging; tachycardia;
D O I
10.1111/j.1540-8167.2006.00371.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
CT Image Integration for AF Ablation. Introduction: Accurate visualization of the complex left atrial (LA) anatomy and the location of an ablation catheter within the chamber is important in the success and safety of ablation for atrial fibrillation (AF). We describe the integration of CT into an electroanatomic mapping (EAM) system and its validation in patients undergoing catheter ablation for AF. Methods and Results: Thirty patients (59.2 +/- 8 years, 25 M) with paroxysmal (12) and persistent (18) AF underwent ablation using CT image integration into an electroanatomic mapping system. CT registration using the pulmonary veins as markers (landmark) was achieved with an error of 6.4 +/- 2.8 mm with repeat registration required in two patients. Registration of the CT by best fit to a electroanatomic geometry (surface) was achieved with an error of 2.3 +/- 0.4 mm. There was no significant difference in the regional LA registration error at superior (1.7 +/- 0.7 mm), inferior (2.2 +/- 1.4 mm), septal (1.7 +/- 0.8 mm), and lateral (1.7 +/- 0.7 mm, P = 0.13) sites. Cardiac rhythm at the time of CT did not have a significant effect on total or regional surface registration accuracy (mean total 2.5 +/- 0.3 in AF patients vs 2.3 +/- 0.5 in SR patients, P = 0.22). The integrated CT was used to guide the encirclement of the pulmonary veins (PV) in pairs with electrical isolation achieved by maintaining ablation along the ablation line in 58 of 60 PV pairs. Postprocedural PV angiography did not demonstrate significant stenosis. Conclusion: CT image integration into an EAM system was successfully performed in patients undergoing catheter ablation for AF. With a greater appreciation of the complex and variable nature of the PV and LA anatomy this new technology may improve the efficacy and safety of the procedure.
引用
收藏
页码:341 / 348
页数:8
相关论文
共 19 条
  • [1] Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation
    Cappato, R
    Calkins, H
    Chen, SA
    Davies, W
    Iesaka, Y
    Kalman, J
    Kim, YH
    Klein, G
    Packer, D
    Skanes, A
    [J]. CIRCULATION, 2005, 111 (09) : 1100 - 1105
  • [2] Pericardial anatomy for the interventional electrophysiologist
    D'Avila, A
    Scanavacca, M
    Sosa, E
    Ruskin, JN
    Reddy, VY
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (04) : 422 - 430
  • [3] EARLEY MJ, 2005, HEART
  • [4] Gepstein L, 1997, CIRCULATION, V95, P1611
  • [5] CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES
    GOLFINOS, JG
    FITZPATRICK, BC
    SMITH, LR
    SPETZLER, RF
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 197 - 205
  • [6] Electrophysiological end point for catheter ablation of atrial fibrillation initiated from multiple pulmonary venous foci
    Haïssaguerre, M
    Jaïs, P
    Shah, DC
    Garrigue, S
    Takahashi, A
    Lavergne, T
    Hocini, M
    Peng, JT
    Roudaut, R
    Clementy, J
    [J]. CIRCULATION, 2000, 101 (12) : 1409 - 1417
  • [7] Multislice computed tomography versus intracardiac echocardiography to evaluate the pulmonary veins before radiofrequency catheter ablation of atrial fibrillation - A head-to-head comparison
    Jongbloed, MRM
    Bax, JJ
    Lamb, HJ
    Dirksen, MS
    Zeppenfeld, K
    van der Wan, EE
    de Roos, A
    Schalij, MJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 343 - 350
  • [8] Freedom from atrial tachyarrhythmias after catheter ablation of atrial fibrillation -: A randomized comparison between 2 current ablation strategies
    Karch, MR
    Zrenner, B
    Deisenhofer, I
    Schreieck, JR
    Ndrepepa, G
    Dong, J
    Lamprecht, K
    Barthel, P
    Luciani, E
    Schömig, A
    Schmitt, C
    [J]. CIRCULATION, 2005, 111 (22) : 2875 - 2880
  • [9] Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging
    Kato, R
    Lickfett, L
    Meininger, G
    Dickfeld, T
    Wu, R
    Juang, G
    Angkeow, P
    LaCorte, J
    Bluemke, D
    Berger, R
    Halperin, HR
    Calkins, H
    [J]. CIRCULATION, 2003, 107 (15) : 2004 - 2010
  • [10] A new approach for catheter ablation of atrial fibrillation: Mapping of the electrophysiologic substrate
    Nademanee, K
    McKenzie, J
    Kosar, E
    Schwab, M
    Sunsaneewitayakul, B
    Vasavakul, T
    Khunnawat, C
    Ngarmukos, T
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (11) : 2044 - 2053