Mass comparison of the 1 kg silicon sphere AVO#3 traceable to the International Prototype K

被引:21
作者
Picard, A. [1 ]
Bignell, N. [2 ]
Borys, M. [3 ]
Downes, S. [4 ]
Mizushima, S. [5 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] Natl Measurement Inst, W Lindfield, NSW 2070, Australia
[3] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[4] Natl Phys Lab, Teddington TW11 0LW, Middx, England
[5] Natl Inst Adv Ind Sci & Technol, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058563, Japan
关键词
PRECISION DETERMINATION; ADSORPTION LAYERS; AIR; DENSITY; ELLIPSOMETRY; STANDARDS; EQUATION; SORPTION; ARGON;
D O I
10.1088/0026-1394/46/1/001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To determine a new value of the Avogadro constant with a relative combined standard uncertainty of 2 x 10(-8), the mass determination of a 1 kg Si-28 sphere is crucial and should be determined with the highest level of accuracy. In the next two years the laboratories involved in the International Avogadro Project should be able to determine the mass of a 1 kg silicon sphere under vacuum with a combined standard uncertainty within 5 mu g. To obtain such a target it is essential to gain experience and to promote cooperation in mass measurement on silicon spheres among the laboratories involved. For this purpose an international comparison has been performed to evaluate the weighing procedure and to reveal the difficulties encountered in the mass determination of a silicon sphere. This particular comparison, which is the first international mass comparison under vacuum conditions, has demonstrated that the reference value for the mass of a 1 kg silicon sphere can be determined traceable to the International Prototype with a standard uncertainty of 4.0 mu g.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 16 条
[1]   VARIANCES, COVARIANCES AND RESTRAINTS IN MASS METROLOGY [J].
BICH, W .
METROLOGIA, 1990, 27 (03) :111-116
[2]  
Cox MG, 2002, METROLOGIA, V39, P589, DOI 10.1088/0026-1394/39/6/10
[3]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981/91) [J].
DAVIS, RS .
METROLOGIA, 1992, 29 (01) :67-70
[4]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981) [J].
GIACOMO, P .
METROLOGIA, 1982, 18 (01) :33-40
[5]   Surface layer impurities on silicon spheres used in determination of the Avogadro constant [J].
Kenny, MJ ;
Netterfield, RP ;
Wielunski, LS ;
Beaglehole, D .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) :233-237
[6]   CODATA recommended values of the fundamental physical constants: 2002 [J].
Mohr, PJ ;
Taylor, BN .
REVIEWS OF MODERN PHYSICS, 2005, 77 (01) :1-107
[7]  
*NAT METR I, MUT REC NAT MEAS STA
[8]  
NIELSEN L, 2002, DFM02R28
[9]   A redetermination of the argon content of air for buoyancy corrections in mass standard comparisons [J].
Park, SY ;
Kim, JS ;
Lee, JB ;
Esler, MB ;
Davis, RS ;
Wielgosz, RI .
METROLOGIA, 2004, 41 (06) :387-395
[10]   Primary mass calibration of silicon spheres [J].
Picard, A. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2006, 17 (10) :2540-2544