Oligosaccharide dehydrogenase-modified graphite electrodes for the amperometric determination of sugars in a flow injection system

被引:20
作者
Tessema, M
Csoregi, E
Ruzgas, T
Kenausis, G
Solomon, T
Gorton, L
机构
[1] LUND UNIV,DEPT ANALYT CHEM,S-22100 LUND,SWEDEN
[2] UNIV ADDIS ABABA,DEPT CHEM,ADDIS ABABA,ETHIOPIA
[3] INST BIOCHEM,ENZYME CHEM LAB,LT-2600 VILNIUS,LITHUANIA
[4] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
D O I
10.1021/ac970127f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enzyme electrodes for the determination of sugars based on solid graphite electrodes modified with oligosaccharide dehydrogenase ''wired'' with an osmium-based one-electron (no proton) acceptor redox hydrogel were studied as sensors in a now injection system. The enzyme and a poly(1-vinylimidazole) (PVI) where every tenth mer is complexed with osmium (4,4'-dimethylbpy)(2)Cl, (denoted PVI(10)dmeOs) were cross-linked with poly(ethylene glycol) (diglycidyl) ether. The electrodes were active for L-arabinose, D-xylose, D-galactose, D-fructose, D-glucose, D-mannose, cellobiose, lactose, maltose, and maltooligosaccharides up to a degree of polymerization of 7. The highest relative response found was for glucose (100%) followed by maltose (40.6%) and lactose (40.6%). Fructose and isomaltotriose gave the lowest responses (<1%). Calibration curves for glucose were strictly linear in the range between 30 and 500 mu M with sensitivity and apparent Michaelis-Menten constant (K-m(app)) Of 23.0 +/- 1.4 mu A mM(-1)cm(-2) and 4.26 +/- 0.95 mM, respectively.
引用
收藏
页码:4039 / 4044
页数:6
相关论文
共 35 条
[1]   ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE [J].
APPELQVIST, R ;
MARKOVARGA, G ;
GORTON, L ;
TORSTENSSON, A ;
JOHANSSON, G .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :237-247
[2]  
CSOREGI E, 1994, ANAL CHEM, V66, P3131
[3]   CELLOBIOSE OXIDASE CROSS-LINKED IN A REDOX POLYMER MATRIX AT AN ELECTRODE SURFACE - A NEW BIOSENSOR [J].
ELMGREN, M ;
LINDQUIST, SE ;
HENRIKSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 341 (1-2) :257-273
[4]   THE INFLUENCE OF FLOW-RATE ON BIOSENSORS BASED ON REDOX ENZYMES INCORPORATED IN A REDOX POLYMER MOUNTED IN A THIN-LAYER FLOW CELL [J].
ELMGREN, M ;
NORDLING, M ;
LINDQUIST, SE .
ANALYTICAL BIOCHEMISTRY, 1993, 215 (02) :261-265
[5]   CHARGE PROPAGATION THROUGH A REDOX POLYMER FILM CONTAINING ENZYMES - EFFECTS OF ENZYME LOADING, PH AND SUPPORTING ELECTROLYTE [J].
ELMGREN, M ;
LINDQUIST, SE ;
SHARP, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1993, 362 (1-2) :227-235
[6]  
ELMGREN M, 1993, THESIS U UPPSALA
[7]   REDOX POLYMER-FILMS CONTAINING ENZYMES .2. GLUCOSE-OXIDASE CONTAINING ENZYME ELECTRODES [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5976-5980
[8]  
GREGG BA, 1991, J PHYS CHEM-US, V95, P5971
[9]   ELECTRICAL CONNECTION OF ENZYME REDOX CENTERS TO ELECTRODES [J].
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1992, 96 (09) :3579-3587
[10]   AMPEROMETRIC RESPONSE TO REDUCING CARBOHYDRATES OF AN ENZYME ELECTRODE BASED ON OLIGOSACCHARIDE DEHYDROGENASE - DETECTION OF LACTOSE AND ALPHA-AMYLASE [J].
IKEDA, T ;
SHIBATA, T ;
TODORIKI, S ;
SENDA, M ;
KINOSHITA, H .
ANALYTICA CHIMICA ACTA, 1990, 230 (01) :75-82