Power-free sequential injection for microchip immunoassay toward point-of-care testing

被引:111
作者
Hosokawa, K [1 ]
Omata, M [1 ]
Sato, K [1 ]
Maeda, M [1 ]
机构
[1] RIKEN, Bioeng Lab, Wako, Saitama 3510198, Japan
关键词
D O I
10.1039/b513424b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper presents a simple fluid handling technique for microchip immunoassay. Necessary solutions were sequentially injected into a microchannel by air-evacuated poly(dimethylsiloxane), and were passively regulated by capillary force at the inlet opening. For heterogeneous immunoassay, microchips are potentially useful for reduction of sample consumption and assay time. However, most of the previously reported microchips have limitations in their use because of the needs for external power sources for fluid handling. In this paper, an on-chip heterogeneous immunofluorescence assay without such an external power source is demonstrated. The microchip consisting of poly(dimethylsiloxane) (PDMS) and glass has a simple structure, and therefore is suitable for single-use applications. Necessary solutions were sequentially injected into a microchannel in an autonomous fashion with the power-free pumping technique, which exploits the high solubility and the rapid diffusion of air in PDMS. For deionized water, this method yielded flow rates of 3-5 nL s(-1) with reproducibility of 4-10%. The inlet opening of the microchannel functioned as a passive valve to hold the solution when the flow was finished. Rabbit immunoglobulin G (rIgG) and human C-reactive protein (CRP) were detected using the microchannel walls as reaction sites. With the sample consumption of 1 mu L and the assay time of similar to 20 min including the antibody immobilization step, the sandwich immunoassay methods for rIgG and CRP exhibited the limits of detection of 0.21 nM (0.21 fmol) and 0.42 nM (0.42 fmol), respectively.
引用
收藏
页码:236 / 241
页数:6
相关论文
共 44 条
  • [1] Immunoassay of infectious agents
    Andreotti, PE
    Ludwig, GV
    Peruski, AH
    Tuite, JJ
    Morse, SS
    Peruski, LF
    [J]. BIOTECHNIQUES, 2003, 35 (04) : 850 - 859
  • [2] Micro total analysis systems. 2. Analytical standard operations and applications
    Auroux, PA
    Iossifidis, D
    Reyes, DR
    Manz, A
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (12) : 2637 - 2652
  • [3] Micromosaic immunoassays
    Bernard, A
    Michel, B
    Delamarche, E
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (01) : 8 - 12
  • [4] BUECHLER KF, 1992, CLIN CHEM, V38, P1678
  • [5] High-sensitivity miniaturized immunoassays for tumor necrosis factor a using microfluidic systems
    Cesaro-Tadic, S
    Dernick, G
    Juncker, D
    Buurman, G
    Kropshofer, H
    Michel, B
    Fattinger, C
    Delamarche, E
    [J]. LAB ON A CHIP, 2004, 4 (06) : 563 - 569
  • [6] Christopoulos Theodore K., 1996, P25, DOI 10.1016/B978-012214730-2/50004-2
  • [7] Patterned delivery of immunoglobulins to surfaces using microfluidic networks
    Delamarche, E
    Bernard, A
    Schmid, H
    Michel, B
    Biebuyck, H
    [J]. SCIENCE, 1997, 276 (5313) : 779 - 781
  • [8] Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays
    Dodge, A
    Fluri, K
    Verpoorte, E
    de Rooij, NF
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (14) : 3400 - 3409
  • [9] Electrokinetically controlled DNA hybridization microfluidic chip enabling rapid target analysis
    Erickson, D
    Liu, XZ
    Krull, U
    Li, DQ
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (24) : 7269 - 7277
  • [10] ERICKSON KA, 1993, CLIN CHEM, V39, P283