Analysis of multiple-acquisition SSFP

被引:153
作者
Bangerter, NK
Hargreaves, BA
Vasanawala, SS
Pauly, JM
Gold, GE
Nishimura, DG
机构
[1] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
关键词
SSFP; steady-state; phase cycling; banding artifact; SNR analysis;
D O I
10.1002/mrm.20052
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Refocused steady-state free precession (SSFP) is limited by its high sensitivity to local field variation, particularly at high field strengths or the long repetition times (TRs) necessary for high resolution. Several methods have been proposed to reduce SSFP banding artifact by combining multiple phase-cycled SSFP acquisitions, each differing in how individual signal magnitudes and phases are combined. These include maximum-intensity SSFP (MI-SSFP) and complex-sum SSFP (CS-SSFP). The reduction in SSFP banding is accompanied by a loss in signal-to-noise ratio (SNR) efficiency. In this work a general framework for analyzing banding artifact reduction, contrast, and SNR of any multiple-acquisition SSFP combination method is presented. A new sum-of-squares method is proposed, and a comparison is performed between each of the combination schemes. The sum-of-squares SSFP technique (SOS-SSFP) delivers both robust banding artifact reduction and higher SNR efficiency than other multiple-acquisition techniques, while preserving SSFP contrast. (C) 2004 Wiley-Liss, Inc.
引用
收藏
页码:1038 / 1047
页数:10
相关论文
共 21 条
  • [1] BANGERTER NK, 2001, P 9 ANN M ISMRM GLAS, P1780
  • [2] Bangerter NK, 2002, P 10 ANN M ISMRM HON, P475
  • [3] SIGNAL INTENSITY IN FAST NMR IMAGING WITH SHORT REPETITION TIMES
    BUXTON, RB
    FISEL, CR
    CHIEN, D
    BRADY, TJ
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (03): : 576 - 585
  • [4] STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE
    CARR, HY
    [J]. PHYSICAL REVIEW, 1958, 112 (05): : 1693 - 1701
  • [5] CASSELMAN JW, 1993, AM J NEURORADIOL, V14, P47
  • [6] Remember true FISP? A high SNR, near 1-second imaging method for T2-like contrast in interventional MRI at .2 T
    Duerk, JL
    Lewin, JS
    Wendt, M
    Petersilge, C
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 203 - 208
  • [7] Frequency-modulated steady-state free precession imaging
    Foxall, DL
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 502 - 508
  • [8] PHASE AND INTENSITY ANOMALIES IN FOURIER TRANSFORM NMR
    FREEMAN, R
    HILL, HDW
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1971, 4 (03) : 366 - &
  • [9] STEADY-STATE FREE PRECESSION IMAGING IN THE PRESENCE OF MOTION - APPLICATION FOR IMPROVED VISUALIZATION OF THE CEREBROSPINAL-FLUID
    HAACKE, EM
    WIELOPOLSKI, PA
    TKACH, JA
    MODIC, MT
    [J]. RADIOLOGY, 1990, 175 (02) : 545 - 552
  • [10] OPPELT A, 1986, Electromedica (English Edition), V54, P15