Characterization of corrosion products on a copper-containing intrauterine device during storage at room temperature

被引:24
作者
Bastidas, JM
Simancas, T
机构
[1] Ctro. Nac. de Invest. Metalurgicas, CSIC, 28040-Madrid
关键词
intrauterine contraceptive device; copper; corrosion products; X-ray photo-electron spectroscopy; Auger electron spectroscopy;
D O I
10.1016/S0142-9612(96)00136-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper studies the characterization of corrosion products formed on corroded and uncorroded copper-containing intrauterine devices stored at room temperature for a period of 30 months. The experimental techniques used were X-ray photo-electron spectroscopy and Auger electron spectroscopy. The compounds found were cuprite (Cu2O) and tenorite (CuO). The latter was the main compound formed on corroded samples, forming thin tarnish films. (C) 1997 Elsevier Science Limited.
引用
收藏
页码:247 / 250
页数:4
相关论文
共 10 条
[2]   EFFECT OF COPPER-CONTAINING INTRAUTERINE CONTRACEPTIVE DEVICES ON HUMAN CELLS IN CULTURE [J].
JONES, RW ;
GREGSON, NM ;
ELSTEIN, M .
BRITISH MEDICAL JOURNAL, 1973, 2 (5865) :520-523
[3]  
KOSONEN A, 1978, FERTIL STERIL, V30, P59
[4]  
Moulder J.F., 1995, HDB XRAY PHOTOELECTR
[5]  
OSTER G, 1975, NEW ENGL J MED, V28, P432
[6]  
OSTER GK, 1972, FERTIL STERIL, V23, P18
[7]   CHARACTERIZATION OF CORROSION PRODUCTS ON CHALCOGRAPHIC COPPER PLATES AFTER 200 YEARS EXPOSURE TO INDOOR ATMOSPHERES [J].
OTERO, E ;
BASTIDAS, JM ;
LOPEZ, W ;
FIERRO, JLG .
WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1994, 45 (07) :387-391
[8]   INDOOR CORROSION OF METALS [J].
RICE, DW ;
CAPPELL, RJ ;
KINSOLVING, W ;
LASKOWSKI, JJ .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1980, 127 (04) :891-901
[9]   ADVENTITIOUS CARBON - THE PANACEA FOR ENERGY REFERENCING [J].
SWIFT, P .
SURFACE AND INTERFACE ANALYSIS, 1982, 4 (02) :47-51
[10]   COPPER RELEASE FROM COPPER-T INTRAUTERINE-DEVICES [J].
TIMONEN, H .