Development and evaluation of a prototype ultrafine particle concentrator

被引:64
作者
Sioutas, C [1 ]
Kim, S [1 ]
Chang, M [1 ]
机构
[1] Univ So Calif, Dept Civil & Environm Engn, Los Angeles, CA 90898 USA
关键词
D O I
10.1016/S0021-8502(98)00769-1
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This paper presents the development and experimental characterization of a prototype ultrafine particle concentrator. In this system, ultrafine particles pass over a pool of warm water where they become saturated with vapor, and subsequently drawn through a condenser, kept at a lower temperature, that allows the ultrafine particles to grow to super-micrometer size by vapor condensation on their surface. In order to increase particle concentration, the grown particles are drawn through a virtual impactor with an approximate 50% cutpoint at 1.5 mu m. The concentrated particles from the minor flow of the virtual impactor finally pass through a diffusion dryer that removes the excess water on the ultrafine particles and returns them back to their original size and relative humidity. In its optimum configuration, the ultrafine concentrator operates at a sampling flow rare of 106.5 or 1101min(-1) and concentrates the ultrafine particles to 3.5 or 71min(-1) by an enrichment factor of approximately 15 and 25.5, respectively. Our experimental results identified saturation of the ultrafine aerosols at 35 degrees C and cooling to 25 degrees C as the optimum temperatures for operation of the ultrafine particle concentrator. Lower temperatures either do not concentrate, or concentrate less efficiently the ultrafine particles. Increasing the saturation temperature to 40 degrees C and cooling to 31 degrees C does not improve the concentration enrichment achieved by the optimum configuration. Our results also indicated that the concentration enrichment does not depend on the chemical composition of the ultrafine aerosol. Hygroscopic ammonium sulfate, volatile ammonium nitrate, hydrophobic polystyrene latex and actual "real-life" indoor air ultrafine particles were all concentrated by practically the same factor. More importantly, the experimental results show that particle concentration occurs without any coagulation, which would have distorted the size distribution of the original ultrafine aerosols. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1001 / 1017
页数:17
相关论文
共 49 条
[1]   CONTINUOUS-FLOW, SINGLE-PARTICLE-COUNTING CONDENSATION NUCLEUS COUNTER [J].
AGARWAL, JK ;
SEM, GJ .
JOURNAL OF AEROSOL SCIENCE, 1980, 11 (04) :343-&
[2]   PARTICLE ACTIVATION AND DROPLET GROWTH-PROCESSES IN CONDENSATION NUCLEUS COUNTER .1. THEORETICAL BACKGROUND [J].
AHN, KH ;
LIU, BYH .
JOURNAL OF AEROSOL SCIENCE, 1990, 21 (02) :249-261
[3]   SPECIATION AND PULMONARY EFFECTS OF ACIDIC SOX FORMED ON THE SURFACE OF ULTRAFINE ZINC-OXIDE AEROSOLS [J].
AMDUR, MO ;
CHEN, LC ;
GUTY, J ;
LAM, HF ;
MILLER, PD .
ATMOSPHERIC ENVIRONMENT, 1988, 22 (03) :557-560
[4]  
ANDERSON KR, 1992, J AIR WASTE MANAGE, V42, P437
[5]   THE ONTARIO AIR-POLLUTION STUDY - IDENTIFICATION OF THE CAUSATIVE AGENT [J].
BATES, DV ;
SIZTO, R .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1989, 79 :69-72
[6]   PULMONARY DISTRIBUTION OF PARTICLES GIVEN BY INTRATRACHEAL INSTILLATION OR BY AEROSOL INHALATION [J].
BRAIN, JD ;
KNUDSON, DE ;
SOROKIN, SP ;
DAVIS, MA .
ENVIRONMENTAL RESEARCH, 1976, 11 (01) :13-33
[7]   AIRWAY HYPERRESPONSIVENESS IN GUINEA-PIGS EXPOSED TO ACID-COATED ULTRAFINE PARTICLES [J].
CHEN, LC ;
MILLER, PD ;
AMDUR, MO ;
GORDON, T .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1992, 35 (03) :165-174
[8]   DESIGN AND PERFORMANCE OF A HIGH-VOLUME COMPOUND ANNULAR DENUDER [J].
COUTANT, RW ;
CALLAHAN, PJ ;
KUHLMAN, MR ;
LEWIS, RG .
ATMOSPHERIC ENVIRONMENT, 1989, 23 (10) :2205-2211
[9]  
DELAMORA JF, 1990, J AEROSOL SCI, V21, P701
[10]   EFFECTS OF INHALABLE PARTICLES ON RESPIRATORY HEALTH OF CHILDREN [J].
DOCKERY, DW ;
SPEIZER, FE ;
STRAM, DO ;
WARE, JH ;
SPENGLER, JD ;
FERRIS, BG .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (03) :587-594