Radiation tolerance of CVD diamond detectors for pions and protons

被引:29
作者
Adam, W
Berdermann, E
Bergonzo, P
Bertuccio, G
Bogani, F
Borchi, E
Brambilla, A
Bruzzi, M
Colledani, C
Conway, J
D'Angelo, P
Dabrowski, W
Delpierre, P
Deneuville, A
Dulinski, W
van Eijk, B
Fallou, A
Fizzotti, F
Foulon, F
Friedl, M
Gan, KK
Gheeraert, E
Hallewell, G
Han, S
Hartjes, F
Hrubec, J
Husson, D
Kagan, H
Kania, D
Kaplon, J
Kass, R
Koeth, T
Krammer, M
Logiudice, A
Lu, R
Mac Lynne, L
Manfredotti, C
Meier, D
Mishina, M
Moroni, L
Noomen, J
Oh, A
Pan, LS
Pernicka, M
Peitz, A
Perera, L
Pirollo, S
Procario, M
Riester, JL
Roe, S
机构
[1] NIKHEF H, NL-1009 DB Amsterdam, Netherlands
[2] Austrian Acad Sci, Inst Hochenergiephys, A-1050 Vienna, Austria
[3] GSI Darmstadt, D-6100 Darmstadt, Germany
[4] CEA Saclay, LETI, CEA Technol Avancees, DEIN,SPE, F-91191 Gif Sur Yvette, France
[5] Politecn Milan, I-20133 Milan, Italy
[6] LENS, Florence, Italy
[7] Univ Florence, Florence, Italy
[8] ULP, CNRS, LEPSI, IN2P3, F-67037 Strasbourg, France
[9] Rutgers State Univ, Piscataway, NJ 08855 USA
[10] Ist Nazl Fis Nucl, I-20133 Milan, Italy
[11] UMM, Fac Phys & Nucl Tech, Krakow, Poland
[12] CPPM, F-13288 Marseille, France
[13] LEPES, Grenoble, France
[14] Univ Turin, I-10124 Turin, Italy
[15] Ohio State Univ, Columbus, OH 43210 USA
[16] CERN, CH-1211 Geneva 23, Switzerland
[17] FNAL, Batavia, IL USA
[18] Inst Expt Phys 2, Hamburg, Germany
[19] Carnegie Mellon Univ, Pittsburgh, PA 15213 USA
[20] Univ Bristol, Bristol BS8 1TL, Avon, England
[21] Univ Toronto, Toronto, ON M5S 1A7, Canada
[22] IIT, Chicago, IL 60616 USA
关键词
diamond; radiation damage; charge signal distribution;
D O I
10.1016/S0168-9002(01)01666-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper gives new results on the radiation tolerance of CVD diamond for irradiation with 300 MeV/c pions and 24 GeV/c protons. The measured charge signal spectrum is compared at several irradiation levels with the spectrum calculated by a model. Irradiation by particles causes damage leading to a decrease of the charge signal. However, both the measurements and the outcome from the model show that for tracker applications this drawback is at least partly counterbalanced by a narrowing of the distribution curve of the charge signal. As a result, the efficiency of a CVD diamond tracker is less affected by irradiation than the mean charge signal. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:686 / 693
页数:8
相关论文
共 8 条
[1]   Pulse height distribution and radiation tolerance of CVD diamond detectors [J].
Adam, W ;
Berdermann, E ;
Bergonzo, P ;
Bertuccio, G ;
Begani, F ;
Borchi, E ;
Brambilla, A ;
Bruzzi, M ;
Colledani, C ;
Conway, J ;
Dangelo, P ;
Dabrowski, W ;
Delpierre, P ;
Deneuville, A ;
Dulinski, W ;
van Eijk, B ;
Fallou, A ;
Fizzotti, F ;
Foulon, F ;
Friedl, M ;
Gan, KK ;
Gheeraert, E ;
Grigoriev, E ;
Hallewell, G ;
Han, S ;
Hartjes, F ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kaplon, J ;
Karl, C ;
Kass, R ;
Krammer, M ;
Logiudice, A ;
Lu, R ;
Manfredotti, C ;
Meier, D ;
Mishina, M ;
Moroni, L ;
Oh, A ;
Pan, LS ;
Pernicka, M ;
Peitz, A ;
Pirollo, S ;
Polesello, P ;
Procario, M ;
Riester, JL ;
Roe, S ;
Rousseau, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 447 (1-2) :244-250
[2]  
BAUER C, 1995, CERNPPE95173
[3]  
CERN LHCC, 2000, 2000011 CERNLHCC
[4]   Proton irradiation of CVD diamond detectors for high-luminosity experiments at the LHC [J].
Meier, D ;
Adam, W ;
Bauer, C ;
Berdermann, E ;
Bergonzo, P ;
Bogani, F ;
Borchi, E ;
Bruzzi, M ;
Colledani, C ;
Conway, J ;
Dabrowski, W ;
Delpierre, P ;
Deneuville, A ;
Dulinski, W ;
van Eijk, B ;
Fallou, A ;
Foulon, F ;
Friedl, M ;
Jany, C ;
Gan, KK ;
Gheeraert, E ;
Grigoriev, E ;
Hallewell, G ;
Hall-Wilton, R ;
Han, S ;
Hartjes, F ;
Hrubec, J ;
Husson, D ;
Kagan, H ;
Kania, D ;
Kaplon, J ;
Kass, R ;
Knöpfle, KT ;
Krammer, M ;
Manfredi, PF ;
Marshall, RD ;
Mishina, M ;
Le Normand, F ;
Pan, LS ;
Palmieri, VG ;
Pernegger, H ;
Pernicka, M ;
Peitz, A ;
Pirollo, S ;
Pretzl, K ;
Re, V ;
Riester, JL ;
Roe, S ;
Roff, D ;
Rudge, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01) :173-180
[5]  
MEIER D, 1999, THESIS U HEIDELBERG
[6]  
MOYAL JE, 1955, PHILOS MAG, V46, P263
[7]   Tracking with CVD diamond radiation sensors at high luminosity colliders [J].
Schnetzer, S ;
Adam, W ;
Bauer, C ;
Berdermann, E ;
Bergonzo, P ;
Bogani, F ;
Borchi, E ;
Brambilla, A ;
Bruzzi, M ;
Colledani, C ;
Conway, J ;
Dabrowski, W ;
DaGraca, J ;
Delpierre, P ;
Deneuville, A ;
Dulinski, W ;
van Eijk, B ;
Fallou, A ;
Fizzotti, F ;
Foulon, F ;
Friedl, M ;
Gan, KK ;
Gheeraert, E ;
Grigoriev, E ;
Hallewell, G ;
Hall-Wilton, R ;
Han, S ;
Hartjes, F ;
Hrubec, J ;
Husson, D ;
Jamieson, D ;
Kagan, H ;
Kania, D ;
Kaplon, J ;
Karl, C ;
Kass, R ;
Knoepfle, KT ;
Krammer, M ;
Logiudice, A ;
Lu, R ;
Manfredi, PF ;
Manfredotti, C ;
Marshall, RD ;
Meier, D ;
Mishina, M ;
Oh, A ;
Pan, LS ;
Palmieri, VG ;
Pernicka, M ;
Pietz, A .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (03) :193-200
[8]  