Chemiluminescence detection for capillary electrophoresis and microchip capillary electrophoresis

被引:70
作者
Huang, XY [1 ]
Ren, JC [1 ]
机构
[1] Shanghai Jiao Tong Univ, Coll Chem & Chem Engn, Shanghai 200240, Peoples R China
基金
中国国家自然科学基金;
关键词
capillary electrophoresis; CE; chemiluminescence; CL; microchip capillary electrophoresis; MCE;
D O I
10.1016/j.trac.2005.07.001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis (CE) has become a very important micro-analytical method in many fields, such as biology, biomedicine, and environmental and food sciences. However, the small injection volume makes it a challenge to achieve high-sensitivity detection. CE and microchip capillary electrophoresis (MCE) coupled with chemiluminescence (CL) detection have certain advantages from combining the high separation efficiency of CE with the high sensitivity of CL. To date, CE-CL and MCE-CL systems have been used successfully for separating metal ions, amino acids, biomarkers, and bio-macromolecules, such as proteins, enzymes and DNA fragments. In this article, we give an overview on the methodological aspects of CL detection with CE and MCE systems, summarize key applications, and discuss future prospects. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:155 / 166
页数:12
相关论文
共 80 条
[1]   CHEMILUMINESCENCE DETECTION IN CAPILLARY ELECTROPHORESIS [J].
BAEYENS, WRG ;
LING, BL ;
IMAI, K ;
CALOKERINOS, AC ;
SCHULMAN, SG .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1994, 6 (03) :195-206
[2]   Determination of codeine, 6-methoxycodeine and thebaine using capillary electrophoresis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW ;
Purcell, SD .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :321-324
[3]   Determination of morphine, oripavine and pseudomorphine using capillary electrophoresis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYST, 2000, 125 (01) :91-95
[4]   CHEMI-LUMINESCENCE LIGHTS UP [J].
BRONSTEIN, I ;
MCGRATH, P .
NATURE, 1989, 338 (6216) :599-600
[5]   END-COLUMN CHEMILUMINESCENCE DETECTOR FOR CAPILLARY ELECTROPHORESIS [J].
DADOO, R ;
SETO, AG ;
COLON, LA ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1994, 66 (02) :303-306
[6]  
DADOO R, 1992, HRC-J HIGH RES CHROM, V15, P133
[7]  
Danet AF, 2000, LUMINESCENCE, V15, P305, DOI 10.1002/1522-7243(200009/10)15:5<305::AID-BIO599>3.0.CO
[8]  
2-X
[9]  
Garcia-Campana A. M., 2001, CHEMILUMINESCENCE AN
[10]   Derivatization of biomolecules for chemiluminescent detection in capillary electrophoresis [J].
García-Campaña, AM ;
Gámiz-Gracia, L ;
Baeyens, WRG ;
Barrero, FA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 793 (01) :49-74