A study on the development of a continuous peristaltic micropump using magnetic fluids

被引:68
作者
Kim, EG [1 ]
Oh, J [1 ]
Choi, B [1 ]
机构
[1] Sogang Univ, Dept Mech Engn, Mapo Ku, Seoul 121742, South Korea
基金
新加坡国家研究基金会;
关键词
micropump; magnetic fluid; micro actuators; MEMS; micromachining;
D O I
10.1016/j.sna.2006.01.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 [电气工程]; 0809 [电子科学与技术];
摘要
This paper presents the development of a peristaltic MF (magnetic fluid) micropump for the purpose of applications of 'lab on a chip', which is the core technology of the medical & biological fields. In the device, magnetic fluids are gathered in the round-shaped channel by the magnetic force, which is applied from the external permanent magnet controlled by stepping motor. The gathered W lump deforms the silicone rubber diaphragm and then the deformed diaphragm pushes the sample liquid in the microchannel. The micropump was fabricated through the conventional MEMS (micromachining) technology. It doesn't have any complicated moving part, but uses magnetic fluids as a driving source. Thus, the proposed micropump can realize more reliability and durability. In addition, the driving method of our 'continuous peristaltic' micropump is different from that of other pumps using cavity sequence. Consequently, it brings out significant improvements in the performance. Furthermore, it cannot only pump in forward and backward directions, but also can control flow rate by adjusting the external permanent magnet. The MF lump also serves as a valve when the stepping motor of micropump stands still. The maximum flow rate of the micropump was 2.8 mu l/min at 4 rpm and 3.8 mu l/min at 8 rpm. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 15 条
[1]
AHN JJ, 2002, IEEE EMBS SPEC TOP C
[2]
[Anonymous], 2001, BIOCHIP TECHNOLOGY
[3]
CUI Z, KNOWLEDGE BASE MICRO
[4]
GREVELL NE, 1997, IEEE T BIOMED ENG, V44
[5]
A ferrofluidic magnetic micropump [J].
Hatch, A ;
Kamholz, AE ;
Holman, G ;
Yager, P ;
Böhringer, KF .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2001, 10 (02) :215-221
[6]
A continuous peristaltic micropump using magnetic fluid [J].
Kim, EG ;
Sim, WC ;
Oh, J ;
Choi, BY .
2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, :509-513
[7]
Tangential magnetic field induced structure in a thin layer of viscous magnetic fluid when developing Rayleigh-Taylor instability [J].
Korovin, VM ;
Kubasov, AA .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 202 (2-3) :547-553
[8]
Kovacs G.T., 1998, Micromachined Transducers Sourcebook
[9]
KOVACS GTA, MICROMACHINED TRANSD, P839
[10]
MAGNETIC FORCES AND SURFACE INSTABILITY IN FERROMAGNETIC FLUIDS [J].
MILLER, CW ;
RESLER, EL .
PHYSICS OF FLUIDS, 1975, 18 (09) :1112-1118