Simultaneous determination of synthetic phosphodiesterase-5 inhibitors found in a dietary supplement and pre-mixed bulk powders for dietary supplements using high-performance liquid chromatography with diode array detection and liquid chromatography-electrospray ionization tandem mass spectrometry

被引:121
作者
Zou, P
Oh, SSY
Hou, PL
Low, MY
Koh, HL
机构
[1] Natl Univ Singapore, Fac Sci, Dept Pharm, Singapore 117543, Singapore
[2] Hlth Sci Author, Ctr Analyt Sci, Singapore 169078, Singapore
关键词
LC-ESI-MS/MS; PDE-5; inhibitor; dietary supplement; adulterants; sildenafil; vardenatil; tadalafil; homosildenafil; hydroxyhomosildenafil; acetildenatil;
D O I
10.1016/j.chroma.2005.11.103
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography-diode array detection (HPLC-DAD) method and a liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method were developed to screen for the presence of synthetic phosphodiesterase-5 (PDE-5) inhibitors and their analogues, namely sildenafil, vardenatil, tadalafil, homosildenafil, acefildenatil and hydroxyhomosildenatil. The methods were applied to pre-market samples submitted to the Health Sciences Authority of Singapore (HSA) for testing. One sample was in the form of capsules while six other samples were pre-mixed bulk powder samples for dietary supplements to be repackaged or formulated into the final dosage forms (usually capsules). Identification of PDE-5 inhibitors and their analogues was achieved by comparing individual peak retention times, UV spectra and mass spectra with those of reference standards. The seven samples were found to contain at least one of the following compounds: sildenafil, vardenafil, hydroxyhomosildenafil, homosildenafil and acetildenafil. The five compounds were simultaneously determined by LC-ESI-MS/MS in multiple reactions monitoring (MRM) scan mode. The method has been validated for accuracy, precision, linearity and sensitivity. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 122
页数:10
相关论文
共 19 条
[1]  
BAYOT J, 2005, INT HERALD TRIB 0528, P15
[2]   Structure elucidation of sildenafil analogues in herbal products [J].
Blok-Tip, L ;
Zomer, B ;
Bakker, F ;
Hartog, KD ;
Hamzink, M ;
ten Hove, J ;
Vredenbregt, M ;
de Kaste, D .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2004, 21 (08) :737-748
[3]   Determinaton of sildenafil citrate and related substances in the commercial products and tablet dosage form using HPLC [J].
Daraghmeh, N ;
Al-Omari, M ;
Badwan, AA ;
Jaber, AMY .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 25 (3-4) :483-492
[4]   Recent findings on natural products with erectile-dysfunction activity [J].
Drewes, SE ;
George, J ;
Khan, F .
PHYTOCHEMISTRY, 2003, 62 (07) :1019-1025
[5]   Simultaneous assay of sildenafil and desmethylsildenafil in human plasma using liquid chromatography-tandem mass spectrometry on silica column with aqueous-organic mobile phase [J].
Eerkes, A ;
Addison, T ;
Weng, ND .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 768 (02) :277-284
[6]   Analysis of undeclared synthetic phosphodiesterase-5 inhibitors in dietary supplements and herbal matrices by LC-ESI-MS and LC-UV [J].
Gratz, SR ;
Flurer, CL ;
Wolnik, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 36 (03) :525-533
[7]  
HERPER M, 2004, FORBES 0721
[8]  
*JAP PHARM FOOD SA, 2004, DISC SO CALL HLTH FO
[9]   Chinese proprietary medicine in Singapore - Regulatory control of toxic heavy metals and undeclared drugs [J].
Koh, HL ;
Woo, SO .
DRUG SAFETY, 2000, 23 (05) :351-362
[10]   HPLC and GC-MS screening of Chinese proprietary medicine for undeclared therapeutic substances [J].
Liu, SY ;
Woo, SO ;
Koh, HL .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :983-992