Determination of organophosphorus pesticides in water by solid-phase microextraction

被引:43
作者
Su, PG [1 ]
Huang, SD [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 300, Taiwan
关键词
gas chromatography-flame photometric detector; solid-phase microextraction; organophosphorus pesticides; polyacrylate; polydimethyl siloxane; water;
D O I
10.1016/S0039-9140(99)00002-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-phase microextraction method coupled with a flame photometric detector was developed for the analysis of organophosphorus pesticides in water. Two kinds of fiber (100 mu m polydimethyl siloxane (PDMS) and 85 mu m polyacrylate (PA) fibers) were used and compared. Parameters that may affect the extraction, such as the duration of absorption and desorption, temperature of absorption, ionic strength, elutropic strength, and concentration of humic acid were investigated. Higher sensitivity and lower detection limits were achieved using a PA fiber than using a PDMS fiber. The detection limit is less than 0.3 mu g l(-1) for most of the analytes, except for mevinphos (420 mu g l(-1)). The precision is better than 9%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:393 / 402
页数:10
相关论文
共 37 条
[1]  
[Anonymous], 1996, ANALYST, DOI DOI 10.1039/an9962100929
[2]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[3]  
ARTHUR CL, 1992, J ENV SCI TECHNOL, V26, P979
[4]   DETERMINATION OF ORGANOPHOSPHORUS COMPOUNDS IN MEDITERRANEAN COASTAL WATERS AND BIOTA SAMPLES USING GAS-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS AND CHEMICAL IONIZATION MASS-SPECTROMETRIC DETECTION [J].
BARCELO, D ;
PORTE, C ;
CID, J ;
ALBAIGES, J .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) :199-209
[5]  
Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI [10.2166/wqrj.1989.010, DOI 10.2166/WQRJ.1989.010]
[6]   DETERMINATION OF NONVOLATILE ORGANIC-COMPOUNDS IN AQUEOUS ENVIRONMENTAL-SAMPLES USING LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
BELLAR, TA ;
BUDDE, WL .
ANALYTICAL CHEMISTRY, 1988, 60 (19) :2076-2083
[7]   Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of alkylphenol ethoxylate surfactants in water [J].
BoydBoland, AA ;
Pawliszyn, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1521-1529
[8]   OPTIMIZATION OF SOLID-PHASE MICROEXTRACTION CONDITIONS FOR DETERMINATION OF PHENOLS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1994, 66 (01) :160-167
[9]   DETERMINATION OF PHENOLS BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHIC ANALYSIS [J].
BUCHHOLZ, KD ;
PAWLISZYN, J .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (13) :2844-2848
[10]   DETERMINATION OF VOLATILE CHLORINATED HYDROCARBONS IN AIR AND WATER WITH SOLID-PHASE MICROEXTRACTION [J].
CHAI, M ;
ARTHUR, CL ;
PAWLISZYN, J ;
BELARDI, RP ;
PRATT, KF .
ANALYST, 1993, 118 (12) :1501-1505