Automated determination of pirlindole enantiomers in plasma by on-line coupling of a pre-column packed with restricted access material to a chiral liquid chromatographic column

被引:18
作者
Chiap, P
Ceccato, A
Gora, R
Hubert, P
Géczy, J
Crommen, J
机构
[1] Univ Liege, Inst Pharm, Dept Pharmaceut Analyt Chem, CHU, B-4000 Liege 1, Belgium
[2] Therabel Res, B-1180 Brussels, Belgium
关键词
pirlindole enantiomers; chiral liquid chromatography; plasma; sample preparation; column-switching; restricted access material;
D O I
10.1016/S0731-7085(01)00647-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fully automated liquid chromatographic method has been developed for the determination of the enantiomers of pirlindole, an antidepressant drug, in human plasma. The method is based on the use of a pre-column packed with restricted access material (RAM) (LiChrospher ADS RP-4) for sample clean-up coupled to a column containing a cellulose tris-(3,5-dimethylphenylcarbamate) based chiral stationary phase (Chiralcel OD-R) for the separation and quantitative analysis of pirlindole enantiomers. A 50-mul plasma volume was injected directly onto the pre-column using a mixture of phosphate buffer (pH 5.0) and methanol (97:3; v/v) as washing liquid. By rotation of a switching valve. the analytes were then eluted in the back-flush mode with the LC mobile phase. A complete separation of pirlindole enantiomers was obtained in 22 min on the Chiralcel OD-R column, using a mobile phase made of a mixture of phosphate buffer (pH 5.0) containing 50 mM sodium perchlorate and acetonitrile (65:35; v/v). The flow-rate was 0.6 ml/min and the analytes were detected fluorometrically using 295 and 340 nm as excitation and emission wavelengths, respectively. The method was then validated and was found to be linear in the 2.5-200 ng/ml range. The limit of detection was lower than 1 ng/ml. Repeatability and intermediate precision at a concentration of 50 ng/ml were about 1.5 and 3.5%, respectively. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:447 / 455
页数:9
相关论文
共 29 条
[1]  
AHAN HY, 1994, J CHROMATOGR B, V653, P163
[2]   Application of the restricted-access precolumn packing material alkyl-diol silica in a column-switching system for the determination of ketoprofen enantiomers in horse plasma [J].
Baeyens, WRG ;
Van der Weken, G ;
Haustraete, J ;
Aboul-Enein, HY ;
Corveleyn, S ;
Remon, JP ;
García-Campaña, AM ;
Deprez, P .
JOURNAL OF CHROMATOGRAPHY A, 2000, 871 (1-2) :153-161
[3]   High-performance liquid chromatography integrated solid-phase extraction in bioanalysis using restricted access precolumn packings [J].
Boos, KS ;
Grimm, CH .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (03) :175-180
[4]   ALKYL-DIOL SILICA (ADS) - RESTRICTED ACCESS PRECOLUMN PACKINGS FOR DIRECT-INJECTION AND COUPLED-COLUMN CHROMATOGRAPHY OF BIOFLUIDS [J].
BOOS, KS ;
RUDOLPHI, A ;
VIELHAUER, S ;
WALFORT, A ;
LUBDA, D ;
EISENBEISS, F .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8) :684-690
[5]   Comparative study of pirlindole, a selective RIMA, and its two enantiomers using biochemical and behavioural techniques [J].
Bruhwyler, J ;
Liégeois, JF ;
Gérardy, J ;
Damas, J ;
Chleide, E ;
Lejeune, C ;
Decamp, E ;
de Tullio, P ;
Delarge, J ;
Dresse, A ;
Géczy, J .
BEHAVIOURAL PHARMACOLOGY, 1998, 9 (08) :731-737
[6]  
BRUHWYLER J, 1993, PHARMACEUT RES, V6, P23
[7]   Simultaneous determination of methylphenobarbital enantiomers and phenobarbital in human plasma by on-line coupling of an achiral precolumn to a chiral liquid chromatographic column [J].
Ceccato, A ;
Boulanger, B ;
Chiap, P ;
Hubert, P ;
Crommen, J .
JOURNAL OF CHROMATOGRAPHY A, 1998, 819 (1-2) :143-153
[8]  
Ceccato A, 1999, ENANTIOMER, V4, P305
[9]   Enantiomeric separation of pirlindole by liquid chromatography using different types of chiral stationary phases [J].
Ceccato, A ;
Hubert, P ;
de Tullio, P ;
Liégeois, JF ;
Felikidis, A ;
Géczy, J ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 18 (4-5) :605-614
[10]   Simultaneous determination of pirlindole enantiomers and dehydropirlindole by chiral liquid chromatography [J].
Ceccato, A ;
Hubert, P ;
de Tullio, P ;
Liégois, JF ;
Stachow, M ;
Géczy, J ;
Crommen, J .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (6-7) :1071-1079