(Bio)sensors for measurement of analytes implicated in food safety: a review

被引:201
作者
Patel, PD [1 ]
机构
[1] Leatherhead Int Ltd, Tech Innovat Grp, Surrey KT22 7RT, England
关键词
sensor; biosensor; agrifood; chemical/microbiological contaminants; commercial instrumentation;
D O I
10.1016/S0165-9936(01)00136-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The analytical technology based on sensors is an extremely wide field, which impacts on all the major industrial sectors, such as pharmaceutical, healthcare, food, agriculture, environment and water. The scope of this review is limited to sensors and biosensors developed over recent years specifically for determining analytes implicated in food safety. The review covers the basic principles and types of sensor formats, reported food-specific applications of sensors in the area of chemical and microbiological contaminant analysis, examples of commercial instrumentation and kits available, and indication of future developments in the sensor field. (C)2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:96 / 115
页数:20
相关论文
共 76 条
  • [1] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1999, 14 (03) : 309 - 316
  • [2] THE DIALYSIS ELECTRODE - A NEW METHOD FOR INVIVO MONITORING
    ALBERY, WJ
    BOUTELLE, MG
    GALLEY, PT
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1992, (12) : 900 - 901
  • [3] CHEMILUMINESCENCE-BASED INHIBITION-KINETICS OF ALKALINE-PHOSPHATASE IN THE DEVELOPMENT OF A PESTICIDE BIOSENSOR
    AYYAGARI, MS
    KAMTEKAR, S
    PANDE, R
    MARX, KA
    KUMAR, J
    TRIPATHY, SK
    AKKARA, J
    KAPLAN, DL
    [J]. BIOTECHNOLOGY PROGRESS, 1995, 11 (06) : 699 - 703
  • [4] Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid
    Bauer, CG
    Eremenko, AV
    EhrentreichForster, E
    Bier, FF
    Makower, A
    Halsall, HB
    Heineman, WR
    Scheller, FW
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (15) : 2453 - 2458
  • [5] Design and use of a general capturing surface in optical biosensor analysis of sulphamethazine in milk
    Bergström, C
    Sternesjö, Å
    Bjurling, P
    Löfås, S
    [J]. FOOD AND AGRICULTURAL IMMUNOLOGY, 1999, 11 (04) : 329 - 338
  • [6] BERNARD A, 1995, EUR J BIOCHEM, V230, P416
  • [7] Beyersdorf-Radeck B, 1998, MICROBIOL RES, V153, P239, DOI 10.1016/S0944-5013(98)80006-2
  • [8] INTEGRATED OPTICAL IMMUNOSENSOR FOR S-TRIAZINE DETERMINATION - REGENERATION, CALIBRATION AND LIMITATIONS
    BIER, FF
    JOCKERS, R
    SCHMID, RD
    [J]. ANALYST, 1994, 119 (03) : 437 - 441
  • [9] DEVELOPMENT OF A FLOW-INJECTION ANALYSIS (FIA) IMMUNOSENSOR FOR THE DETECTION OF ESCHERICHIA-COLI
    BOUVRETTE, P
    LUONG, JHT
    [J]. INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 1995, 27 (2-3) : 129 - 137
  • [10] Immunoelectrochemical assays for bacteria: Use of epifluorescence microscopy and rapid-scan electrochemical techniques in development of an assay for Salmonella
    Brewster, JD
    Gehring, AG
    Mazenko, RS
    VanHouten, LJ
    Crawford, CJ
    [J]. ANALYTICAL CHEMISTRY, 1996, 68 (23) : 4153 - 4159