A fault tolerant doubly fed induction generator wind turbine using a parallel grid side rectifier and series grid side converter

被引:213
作者
Flannery, Patrick S. [1 ]
Venkataramanan, Giri [1 ]
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
关键词
doubly fed induction generator (DFIG); dynamic voltage restorer; voltage sag ride-through; wind turbine;
D O I
10.1109/TPEL.2008.921179
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With steadily increasing wind turbine penetration, regulatory standards for grid interconnection have evolved to require that wind generation systems ride-through disturbances such as faults and support the grid during such events. Conventional modifications to the doubly fed induction generation (DFIG) architecture for providing ride-through result in compromised control of the turbine shaft and grid current during fault events. A DFIG architecture in which the grid side converter is connected in series as opposed to parallel with the grid connection has shown improved low voltage ride through but poor power processing capabilities. In this paper, a unified DFIG wind turbine architecture which employs a parallel grid side rectifier and series grid side converter is presented. The combination of these two converters enables unencumbered power processing and robust voltage disturbance ride through. A dynamic model and control structure for this architecture is developed. The operation of the system is illustrated using computer simulations.
引用
收藏
页码:1126 / 1135
页数:10
相关论文
共 16 条
  • [1] [Anonymous], P 38 ANN POW EL SPEC
  • [2] Dynamic modeling of doubly fed induction generator wind turbines
    Ekanayake, JB
    Holdsworth, L
    Wu, XG
    Jenkins, N
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) : 803 - 809
  • [3] ERLICH I, 2006, P IEEE POW ENG SOC G, P7
  • [4] ERLICH I, 2005, P IEEE POW ENG SOC G, P2230
  • [5] FLANNERY P, 2007, POW CONV C NAG 2007, P1442, DOI DOI 10.1109/PCCON.2007.373154
  • [6] HELLER M, 1997, P 7 EUR C POW EL APP, V2, P707
  • [7] Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder
    Hopfensperger, B
    Atkinson, DJ
    Lakin, RA
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2000, 147 (04): : 241 - 250
  • [8] Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    Lopez, Jesus
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) : 709 - 717
  • [9] Marin D., 2006, P INT C IND TECHNOL, P316
  • [10] A detailed comparison of system topologies for dynamic voltage restorers
    Nielsen, JG
    Blaabjerg, F
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) : 1272 - 1280