Ultrasound imaging is widely used in animal breeding to provide in vivo estimated of the carcass composition of candidates for selection Although the technique is less accurate than more recent medical imaging methods, such as X-ray computed tomography and magnetic resonance imaging, it is relatively cheap and mobile. Therefore large numbers of animals can be measured. Most current ultrasound scanners required some degree of manual interpretation of images, which is time consuming and liable to vary both between and within individuals. Hence, this study investigated the automatic interpretation of ultrasound scans from sheep. A computer algorithm is proposed for identifying tissue boundaries. Estimated of tissue depth are shown to be comparable with those obtained by manual interpretation, for images of 72 sheep scanned twice at the position of the 13th thoracic vertebra. The root-mean-square errors of subcutaneous fat depth and m. longissimus muscle depth were 0.7 mm and 1.7 mm, respectively.
引用
收藏
页码:309 / 315
页数:7
相关论文
共 16 条
[1]  
ABDALLA I, 1994, THESIS U EDINBURGH
[2]  
Alliston J. C., 1983, Sheep production., P75
[3]   STRUCTURAL IMAGE-RESTORATION THROUGH DEFORMABLE TEMPLATES [J].
AMIT, Y ;
GRENANDER, U ;
PICCIONI, M .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1991, 86 (414) :376-387
[4]  
[Anonymous], 1992, SHAPE DETECTION COMP
[5]   TRAINABLE MODELS FOR THE INTERPRETATION OF BIOMEDICAL IMAGES [J].
BALDOCK, RA .
IMAGE AND VISION COMPUTING, 1992, 10 (06) :444-450
[6]   USE OF ACTIVE SHAPE MODELS FOR LOCATING STRUCTURE IN MEDICAL IMAGES [J].
COOTES, TF ;
HILL, A ;
TAYLOR, CJ ;
HASLAM, J .
IMAGE AND VISION COMPUTING, 1994, 12 (06) :355-365
[7]  
Glasbey CA., 1995, IMAGE ANAL BIOL SCI
[8]  
LIN WJ, 1991, LECT NOTES COMPUT SC, V511, P285, DOI 10.1007/BFb0033760
[9]   AN ADAPTIVE WEIGHTED MEDIAN FILTER FOR SPECKLE SUPPRESSION IN MEDICAL ULTRASONIC IMAGES [J].
LOUPAS, T ;
MCDICKEN, WN ;
ALLAN, PL .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1989, 36 (01) :129-135
[10]  
Miles C. A., 1984, In vivomeasurement of body composition in meat animals., P93