Refrigerant mass charge distribution in a domestic refrigerator.: Part I:: Transient conditions

被引:52
作者
Björk, E [1 ]
Palm, B [1 ]
机构
[1] Royal Inst Technol, Dept Energy Technol, SE-10044 Stockholm, Sweden
关键词
domestic refrigerator; charge inventory; capillary tube;
D O I
10.1016/j.applthermaleng.2005.10.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experimental results are presented of the refrigerant mass charge distribution in a steadily cycling domestic refrigerator. In detail it is shown how the charge is displaced at compressor start-up and shut-down. At start-Lip it was found that the charge was temporarily displaced towards the condenser before returning to a steady state distribution in the latter part of the on-period. As a result, initially the evaporator was starved with a lowered evaporation temperature and a peak 10 degrees C superheat. The superheat disappeared within 3 min as the evaporator was gradually refilled with refrigerant. At shut-down the pressure equalised within 3 min as refrigerant was pushed into the evaporator from the condenser. The losses due to charge displacements were estimated to 11% (capacity) and 9% (efficiency). Possible ways to reduce the losses are discussed. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:829 / 837
页数:9
相关论文
共 20 条
[1]
[Anonymous], ASHRAE T
[2]
A simple technique for refrigerant mass measurement [J].
Björk, E .
APPLIED THERMAL ENGINEERING, 2005, 25 (8-9) :1115-1125
[3]
BJORK E, 2002, P ZER LEAK MIN CHARG
[4]
DYNAMIC SIMULATION AND OPTIMAL MATCHING OF A SMALL-SCALE REFRIGERATION SYSTEM [J].
CHEN, ZJ ;
LIN, WH .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (06) :329-335
[5]
Coulter WH, 1997, ASHRAE TRAN, V103, P587
[6]
Dynamic simulation of natural convection bypass two-circuit cycle refrigerator-freezer and its application - Part I: Component models [J].
Ding, GL ;
Zhang, CL ;
Lu, ZL .
APPLIED THERMAL ENGINEERING, 2004, 24 (10) :1513-1524
[7]
X-ray investigation of a domestic refrigerator.: Observations at 25°C ambient temperature [J].
Inan, C ;
Gonul, T ;
Tanes, MY .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2003, 26 (02) :205-213
[8]
JAKOBSEN A, THESIS TU DENMARK
[9]
Janssen M.J.P., 1992, INT J REFRIGERATION, V15
[10]
JANSSEN MJP, 1988, P PURD IIR C 18 21 J