Detection of lesions in multiple sclerosis by 2D FLAIR and single-slab 3D FLAIR sequences at 3.0 T: initial results

被引:72
作者
Bink, A
Schmitt, M
Gaa, J
Mugler, JP
Lanfermann, H
Zanella, FE
机构
[1] Goethe Univ Frankfurt, Dept Neuroradiol, D-60528 Frankfurt, Germany
[2] Siemens Med Solut, Erlangen, Germany
[3] Univ Virginia, Dept Radiol, Charlottesville, VA USA
[4] Univ Virginia, Dept Biomed Engn, Charlottesville, VA USA
关键词
sclerosis; multiple; brain; 2D/3D FLAIR; 3.0; Tesla;
D O I
10.1007/s00330-005-0107-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to compare conventional 2D FLAIR and single-slab 3D FLAIR sequences in the detection of lesions in patients with multiple sclerosis. Eight patients with MS were examined at 3.0 T by using a 2D FLAIR sequence and a single-slab 3D FLAIR sequence. A comparison of lesion detectability was performed for the following regions: periventricular, nonperiventricular/juxtacortical and infratentorial. The contrast-to-noise ratios (CNRs) between lesions and brain tissue and CSF were calculated for each sequence. A total of 424 lesions were found using the 2D FLAIR sequence, while with the 3D FLAIR sequence 719 lesions were found. With the 2D FLAIR sequence, 41% fewer lesions were detected than with the 3D FLAIR sequence. Further, 40% fewer supratentorial and 62.5% fewer infratentorial lesions were found with the 2D FLAIR sequence. In images acquired with the 3D FLAIR sequence, the lesions had significantly higher CNRs than in images acquired with the 2D FLAIR sequence. These are the first results using a single-slab 3D FLAIR sequence at 3.0 T for detection of lesions in patients with MS. With the 3D FLAIR sequence significantly higher CNRs were achieved and significantly more lesions in patients with MS were detected.
引用
收藏
页码:1104 / 1110
页数:7
相关论文
共 24 条
[1]   3D fast FLAIR: A CSF-nulled 3D fast spin-echo pulse sequence [J].
Barker, GJB .
MAGNETIC RESONANCE IMAGING, 1998, 16 (07) :715-720
[2]   Comparison of MRI criteria at first presentation to predict conversion to clinically definite multiple sclerosis [J].
Barkhof, F ;
Filippi, M ;
Miller, DH ;
Scheltens, P ;
Campi, A ;
Polman, CH ;
Comi, G ;
Ader, HJ ;
Losseff, N ;
Valk, J .
BRAIN, 1997, 120 :2059-2069
[3]  
Bastianello S, 1997, AM J NEURORADIOL, V18, P699
[4]  
BUSSE RF, 2005, P INT SOC MAGN RES M, P2344
[5]  
DECOENE B, 1992, AM J NEURORADIOL, V13, P1555
[6]   Quantitative assessment of MRI lesion load in multiple sclerosis - A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery [J].
Filippi, M ;
Yousry, T ;
Baratti, C ;
Horsfield, MA ;
Mammi, S ;
Becker, C ;
Voltz, R ;
Spuler, S ;
Campi, A ;
Reiser, MF ;
Comi, G .
BRAIN, 1996, 119 :1349-1355
[7]   USE OF FLUID ATTENUATED INVERSION RECOVERY (FLAIR) PULSE SEQUENCES IN MRI OF THE BRAIN [J].
HAJNAL, JV ;
BRYANT, DJ ;
KASUBOSKI, L ;
PATTANY, PM ;
DECOENE, B ;
LEWIS, PD ;
PENNOCK, JM ;
OATRIDGE, A ;
YOUNG, IR ;
BYDDER, GM .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (06) :841-844
[8]   Accuracy for detection of simulated lesions: Comparison of fluid-attenuated inversion-recovery, proton density-weighted, and T2-weighted synthetic brain MR imaging [J].
Herskovits, EH ;
Itoh, R ;
Melhem, ER .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (05) :1313-1318
[9]   Suppression of cerebrospinal fluid and blood flow artifacts in FLAIR MR imaging with a single-slab three-dimensional pulse sequence: Initial experience [J].
Kallmes, DF ;
Hui, FK ;
Mugler, JP .
RADIOLOGY, 2001, 221 (01) :251-255
[10]   Routine clinical brain MRI sequences for use at 3.0 Tesla [J].
Lu, HZ ;
Nagae-Poetscher, LM ;
Golay, X ;
Lin, D ;
Pomper, M ;
van Zijl, PCM .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 22 (01) :13-22