High-performance liquid chromatographic determination of diclofenac in human plasma after solid-phase extraction

被引:96
作者
Arcelloni, C
Lanzi, R
Pedercini, S
Molteni, G
Fermo, I
Pontiroli, A
Paroni, R
机构
[1] San Raffaele Sci Inst, Dept Lab Med, Lab Seperat Tech, I-20132 Milan, Italy
[2] Sch Med, I-20132 Milan, Italy
[3] San Raffaele Sci Inst, Dept Internal Med, I-20132 Milan, Italy
[4] Univ Milan, Unit Metab Dis, I-20122 Milan, Italy
来源
JOURNAL OF CHROMATOGRAPHY B | 2001年 / 763卷 / 1-2期
关键词
diclofenac;
D O I
10.1016/S0378-4347(01)00383-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel high-performance liquid chromatographic (HPLC) method for the quantification of diclofenac in human plasma was set up. Samples, added with ibuprofen (used as internal standard) were purified by solid-phase extraction using Abselut Nexus cartridges (Varian) not requiring pre-conditioning. Drugs of interest were eluted directly into the autosampler vials and injected. The recovery of diclofenac was 92%, the analysis lasted 7 min with a sensitivity of 5 ng/ml and intra- and inter-day RSDs of 3 and 8%, respectively. The pharmacokinetics of diclofenac after oral and rectal administration in 10 healthy volunteers are reported. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 9 条