Effects of contact lens multipurpose solutions on human corneal epithelial survival and barrier function

被引:38
作者
Chuang, Eliseu Y. [1 ]
Li, De-Quan [1 ]
Bian, Fang [1 ]
Zheng, Xiaofen [1 ]
Pflugfelder, Stephen C. [1 ]
机构
[1] Baylor Coll Med, Cullen Eye Inst, Dept Ophthalmol, Ocular Surface Ctr, Houston, TX 77030 USA
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2008年 / 34卷 / 05期
关键词
multipurpose solutions; cornea; apoptosis; barrier function; tight junction proteins;
D O I
10.1097/ICL.0b013e3181842518
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose. To examine the effect of 4 commercially available contact lens multipurpose solutions (MPS) on the viability and barrier function Of human corneal epithelial cells in vitro. Methods. Immortalized human corneal epithelial cells were exposed to 4 solutions. MPS A, B, C, and D with Culture medium and Hanks' Balanced Salt Solution as controls. MTT assay was used to evaluate cell viability. ApopTag Fluorescein Apoptosis assay was used to detect cell death in situ. Corneal epithelial barrier function was evaluated by fluorescein permeability and immunofluorescent staining for tight junction proteins zonula occludens (ZO)-1 and occludin. Results. Corneal epithelial survival rates, evaluated by MTT assay showed no statistical difference between MPS A and the Culture medium or Hanks' Balanced Salt Solution controls. MPS B, C, and D were associated with significantly less cell survival than the controls after exposure for 6 hrs (all P<0.01). Compared with the controls. the MPS A did not increase cell apoptosis, whereas the other 3 caused higher apoptotic rates. The epithelial permeability after exposure to MPS A was similar to controls and significantly lower than MPS B and MPS D (P<0.01). The tight junction proteins ZO-1 and occludin were well maintained after exposure to MPS A. In contrast, the expression of ZO-1 and occludin were largely disturbed by the other 3 MPS Solutions. Conclusions. The current marketed contact lens MPS may have negative effects on human corneal epithelial viability and barrier function. Among 4 MPS studied, MPS A maintains the cell viability and barrier function significantly better than other 3 marketed products.
引用
收藏
页码:281 / 286
页数:6
相关论文
共 20 条
[1]
ARAKISASAKI K, 1995, INVEST OPHTH VIS SCI, V36, P614
[2]
Immortalization of human corneal endothelial cells using electroporation protocol optimized for human corneal endothelial and human retinal pigment epithelial cells [J].
Bednarz, J ;
Teifel, M ;
Friedl, P ;
Engelmann, K .
ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (02) :130-136
[3]
Characterization of putative stem cell phenotype in human limbal epithelia [J].
Chen, Z ;
De Paiva, CS ;
Luo, LH ;
Kretzer, FL ;
Pflugfelder, SC ;
Li, DQ .
STEM CELLS, 2004, 22 (03) :355-366
[4]
ABCG2 transporter identifies a population of clonogenic human limbal epithelial cells [J].
De Paiva, CS ;
Chen, Z ;
Corrales, RM ;
Pflugfelder, SC ;
Li, DQ .
STEM CELLS, 2005, 23 (01) :63-73
[5]
DUTOT M, 2008, EYE
[6]
Effects of multipurpose solutions on corneal epithelial tight junctions [J].
Imayasu, Masaki ;
Shiraishi, Atsushi ;
Ohashi, Yuichi ;
Shimada, Shoichi ;
Cavanagh, H. Dwight .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (01) :50-55
[7]
Microbial keratitis - Predisposing factors and morbidity [J].
Keay, L ;
Edwards, K ;
Naduvilath, T ;
Taylor, HR ;
Snibson, GR ;
Forde, K ;
Stapleton, F .
OPHTHALMOLOGY, 2006, 113 (01) :109-116
[8]
Keay L, 2007, EYE CONTACT LENS, V33, P362
[9]
Keay Lisa, 2007, Eye Contact Lens, V33, P346, DOI 10.1097/ICL.0b013e318157c49d
[10]
Factors affecting the morbidity of contact lens-related microbial keratitis: A population study [J].
Keay, Lisa ;
Edwards, Katie ;
Naduvilath, Thomas ;
Forde, Kevin ;
Stapleton, Fiona .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (10) :4302-4308